<CH2 sending>
Slot NO.3
save to address 1 of shared
memory of SCU
1 word of data
from W10
Save to W15
1 word of data
from address 751 of shared
memory of SCU
<CH1 receiving>
<Data comparison>
Turns on when the data are not
identical.
R3.2
R4.2
WRITE
To = 03 : 501
Sz = 1
Fr =W10
M0.4
R3.2
R4.2
M0.5
M0.4
M0.4
M0.5
R4.2
R4.2
R3.1
R4.1
M0.6
R3.1
R4.1
M0.7
READ
To = W15
Sz = 1
Fr =03:751
M0.6
Slot NO.3
M0.6
M0.7
R4.1
R4.1
M0.7
M0.9
W10 < > W15
sent data
received data
M0.8
M5.0
M0.9
R5.0