23
Using READ in WinFPST
(Receiving from external RS232C (RS485) device)
When SCU is installed in the first slot of PLC system and external
RS232C (RS485) is connected to CH1.
Using WRITE in WinFPST
(Transmitting to external RS232C (RS485) device)
When SCU is installed in the first slot of PLC system and external
RS232C (RS485) is connected to CH1.
F150 (READ)
(Data READ from
high function unit.)
Condition for READ
Condition for READ
completion
READ
READ completion signal
(Output to the SCU unit)
X1: For CH1 receiving
X1 turns on when normal data is input
to the RS232C (RS485) device
connected to CH1.
Y11: For CH1 receiving
When reading received data from
shared memory, turn on Y11.
Turn on Y11 when X1 is turned off.
X1
Y11
X1
Y11
R100
R101
R100
Y11
Y11
R100
R101
F151 (WRT)
(Data WRITE to
high-function unit )
Condition for
WRITE
Condition for
WRITE
completion
WRITE
WRITE completion
signal
(Write to the SCU unit)
X0: For CH1 sending
When the SCU received correct data,
X0 turns on.
Y10: For CH1 sending
When writing sending data to shared
memory,
turn on Y10.
Turn off Y10 when X0 is turned on.
XO
Y1O
XO
Y1O
R104
R103
Y1O
Y1O
R103
R104
R103