Sequence Program - ASCII format self-test ladder program (for WinGPC)
( )
( )
( )
( )
( )
( )
( )
<CH1 sending>
Slot NO.3
save to address 1 of shared
memory of SCU
1 word of data
from W0
Save to W5
1 word of data
from address 751 of shared
memory of SCU
<CH2 receiving>
<Data comparison>
Turns on when the data are not
identical.
R3.0
R4.0
WRITE
To = 03 : 1
Sz = 1
Fr =W0
M0.0
R3.0
R4.0
M0.1
M0.0
M0.0
M0.1
R4.0
R4.0
R3.3
R4.3
M0.2
R3.3
R4.3
M0.3
READ
To = W5
Sz = 1
Fr =03:751
M0.0
Slot NO.3
M0.2
M0.3
R4.3
R4.3
M0.3
M0.8
W0 < > W5
sent data
received data