When F-20 = ON, parameter values can be displayed but cannot be modified (except
F-20). Entering the factory-set password number (257) toggles the state of the
lockout. Refer to section 8.2, Ensuring Program Security for this procedure.
Important: There is no visual indication of the status of this feature. You must access
F-20 to verify its current value (ON or OFF).
.
The avoidance band can help alleviate problems with vibrations/harmonics at a
specific operating frequency of the driven motor or machinery. Refer to the F-22
parameter description for more information.
.
This parameter is used with parameter F-21 (Avoidance Frequency). The drive can
accelerate and decelerate through the avoidance band. However, it cannot operate at
a steady state at any of the avoidance band frequencies. Setting F-22 to 0 disables
the avoidance frequency.
F-20 Password Lockout Enable
This parameter
enables or disables
parameter password
protection.
Parameter Range:
Default Setting:
Step Size:
OFF = Password lockout disabled (parameters can be
modified)
ON = Password lockout enabled (parameters cannot be
modified)
OFF
N/A
!
ATTENTION: It is the user’s responsibility to determine how to distribute
the password. Reliance Electric is not responsible for unauthorized
access violations within the user’s organization.
F-21 Avoidance Frequency
This parameter
specifies the midpoint
of the avoidance band
selected in F-22.
Parameter Range:
Default Setting:
Step Size:
Minimum speed to maximum speed (Hz)
5.0
0.10 Hz
F-22 Avoidance Bandwidth
This parameter sets
the avoidance
bandwidth. Any
frequency that falls
within the avoidance
band results in a
generated frequency
below the bandwidth
Parameter Range:
Default Setting:
Step Size:
0 to 30 Hz (0 = avoidance frequency disabled)
0
0.10 Hz
Summary of Contents for Reliance SP500
Page 1: ...Instruction Manual SP500 AC Drive Installation and Operation Manual Version 3 1 D2 3356 5 ...
Page 6: ...IV SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 8: ...VI SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 10: ...1 2 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 13: ...Learning About the SP500 Drive 2 3 Figure 2 1 SP500 System Diagram ...
Page 15: ...Learning About the SP500 Drive 2 5 Figure 2 3 Regulator Board Component Locations ...
Page 24: ...2 14 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 27: ...SP500 System Planning 3 3 Figure 3 3 Enclosure C Dimensions Figure 3 4 Enclosure D Dimensions ...
Page 37: ...Installing the Drive 4 3 Figure 4 2 Enclosure B Wire Routing Locations ...
Page 39: ...Installing the Drive 4 5 Figure 4 4 Enclosure D Wire Routing Locations ...
Page 44: ...4 10 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 56: ...5 12 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 60: ...6 4 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 68: ...7 8 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 86: ...8 18 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 110: ...E 8 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 118: ...Index 4 SP500 AC Drive Installation and Operation Manual Version 3 1 ...
Page 120: ......
Page 121: ......