Connection Wire Sizes
Use the following table as a guideline for wire sizes to make the connections.
Table 17 - PowerFlex 6000T Drive Connection Wires Size
AWG or MCM
Diameter (in.)
Diameter (mm)
Cross-sectional Area (mm
2
)
750
0.8660
22.00
380,031
700
0.8370
21.25
354,695
600
0.7750
19.67
304,025
500
0.7070
17.96
253,354
450
0.6710
17.04
228,018
400
0.6320
16.06
202,683
350
0.5920
15.03
177,348
300
0.5480
13.91
152,012
250
0.5000
12.70
126,677
0000 (4/0)
0.4600
11.68
107,160
000 (3/0)
0.4096
10.40
84,970
00 (2/0)
0.3648
9.27
67,400
0 (1/0)
0.3249
8.25
53,460
1
0.2893
7.35
42,390
2
0.2576
6.54
33,610
3
0.2294
5.83
26,650
4
0.2043
5.19
21,140
5
0.1819
4.62
16,760
6
0.1620
4.11
13,290
7
0.1443
3.67
10,550
8
0.1285
3.26
8360
9
0.1144
2.91
6630
10
0.1019
2.59
5260
11
0.0907
2.30
4170
12
0.0808
2.05
3310
13
0.0720
1.83
2630
14
0.0641
1.63
2080
15
0.0571
1.45
1650
16
0.0508
1.29
1310
17
0.0453
1.15
1040
18
0.0403
1.02
820
19
0.0359
0.91
650
20
0.0320
0.81
520
21
0.0285
0.72
410
22
0.0254
0.65
330
23
0.0226
0.57
260
24
0.0201
0.51
200
25
0.0179
0.45
160
26
0.0159
0.40
130