Chapter 2
CIP Services and User-created Tags
58
Rockwell Automation Publication 1756-PM020F-EN-P - January 2019
•
hourlyCount[11] = 0x0b
•
rate = 1.0
See also
Example of reading an entire structure
The following is an example of reading an entire structure.
Message Request Field
Bytes
Description
Request Service
4C
Read Tag Service (Request)
Request Path Size
08
Request Path is 8 words (16 bytes) long
Request Path
91 0E 4D 61 63 68 69 6E
65 53 75 6D 6D 61 72 79
ANSI Ext. Symbol Segment for
Machine Summary
Request Data
01 00
Number of elements to read (1)
The data returned would be packed like this:
Message Reply Field
Bytes
Description
Reply Service
CC
Read Tag Service (Reply)
Reserved
00
General Status
00
Success
Extended Status Size
00
No Extended Status
Reply Data
A0 02 CD 9E
=Tag Type Service Parameter (The Structure Handle, Template Instance Attribute 1.
See Step 3.)
01
= host SINT (for BOOLs)
00
= Pad byte
00
= Pad byte
00
= Pad byte
00 00
= hourlyCount[0] (array of INT)
01 00
= hourlyCount[1]
02 00
= hourlyCount[2]
03 00
= hourlyCount[3]
04 00
= hourlyCount[4]
05 00
= hourlyCount[5]
06 00
= hourlyCount[6]
07 00
= hourlyCount[7]
08 00
= hourlyCount[8]
09 00
= hourlyCount[9]
0a 00
= hourlyCount[10]
0b 00
= hourlyCount[11]
00 00 80 3F
= rate (REAL)
Example of reading an entire
structure