84
Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
Chapter 6 Installation and Wiring
See
for a configuration for muting sensors that are connected at the
450L-APR-MU-8 connection plug-in.
Table 38 - Pin Assignment — Cat. No. 450L-APR-MU-8 (Configured for (a) No Muting, or for (b) Muting
Sensors Connected at Cascading 450L-APC-IO-8 Plug-in)
Receiver Bottom Plug-in Face View
of Convex M12 8-pin (DC Micro)
View
Pin No.
Signal Receiver
1
Auxiliary output (OSSD emulation)
2
+24V DC
3
Functional earth FE
4
EDM (Input)
(1)
(1)
If set with DIP switches.
5
OSSD1
6
OSSD2
7
0V (GND)
8
Start
/mute dependent override
ATTENTION:
The Auxiliary output is only a status output for diagnosis
purposes to connect, for example, an indicator lamp. Do not use this output
for safety purposes.
Table 39 - Pin Assignment — Cat. No. 450L-APR-MU-8 if Two-sensor Muting Are Connected at the
Connection Plug-in Are Configured (450L-E Safety Light Curtains Only)
Receiver Bottom Plug-in Face View
of Convex M12 8-pin (DC Micro)
View
Pin No.
Signal Receiver
1
Sensor 1
2
+24V DC
3
Functional earth FE
4
Sensor 2
5
OSSD1
6
OSSD2
7
0V (GND)
8
Start
(1)
/mute dependent override
(1)
If set with DIP switches.
ATTENTION:
The Auxiliary output is only a status output for diagnosis
purposes to connect, for example, an indicator lamp. Do not connect this
output to fulfill safety functions.