82
Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
Chapter 6 Installation and Wiring
Plug-in Installation
To maintain the IP65 rating, the slot covers must be inserted fully into the light
curtain. If the slot cover has been removed, it must be replaced with a plug-in
that must be properly inserted into the light curtain.
shows example
of correct and incorrect installation.
Transmitter Plug-in
shows the plug-ins that can make a transceiver a transmitter.
…
show the pinout connections for each plug-in.
Figure 66 - Transmitter Plug-ins
Figure 65 - Plug-in Installation Examples
Correct Incorrect
Cap fully seated
Cap missing
Gasket in groove
No nicks, splits, or flat spots
Gasket mis-located
Fully seated, screws tight
Screws not torqued
450L-APT-PW-5
450L-APT-PW-8
450L-APU-UN-8
Transmitter
Receiver
Plug-in: