Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
163
Chapter 9 Connected Components Workbench Software
1. In the Project Organizer (see
), right-click the device name or
its icon (450L_1). Then select either Update Firmware 450K-stick or
Update Firmware OID (450L-AD-OID).
Figure 176 - Project Organizer: Device > Update Firmware
2. Follow the instructions in the message box (see
). If you are
updating the firmware in the OID, then the OID must not be mounted on
the light curtain. If you are updating the firmware in the light curtain,
then the OID must be mounted on the light curtain with the light curtain
powered. Click OK.
Figure 177 - Stick or OID Connection
shows the Connection Browser with connections to the Stick
and the OID.
3. In the Connection Browser, expand the AB_VBP-1. Both the OID and the
safety light curtain are shown. One of the two always have an X over its
icon. If you are updating the safety light curtain, the OID is not available.
If you are updating the OID, the safety light curtain is not available. Click
the Bulletin 450L to select it. Click OK.
Figure 178 - Connection Browser
4. In
, verify the target revision or select a revision from the pull-
down menu and click Update.
Figure 179 - Update Hardware
Progress of the update is shown on
Stick
OID
Stick
OID
Stick
OID