Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
125
Chapter 9 Connected Components Workbench Software
Figure 107 - GPIO Selection Settings
lists the possible selections and their descriptions. The possible
selection choices are dependent on the hardware and automatically
determined by the Connected Components Workbench software. See
for detailed descriptions of the selections.
Item
Description
1
Mandatory inputs
2
Mandatory muting sensors
3
Optional inputs or outputs
Table 59 - GPIO Selections
I/O
Selection
Description
Input
Activate subconfiguration #
Activates this subconfiguration. Only one subconfiguration can be
active. At least one subconfiguration must be active.
External device monitoring
Monitors external devices that the light curtain OSSD outputs drive.
Laser alignment ON/OFF
Turns the integrated laser alignment function ON and OFF.
Manual (re)start
Input turns on the OSSD outputs if the light curtain is clear.
Mute dependent override
Turns on the OSSD outputs if a muting error occurs and the light
curtain is blocked.
Muting sensor #
Indicates that a sensor is blocked.
Start release
With the light curtain clear, the start release input turns on the
OSSD outputs on the leading edge of the signal.
Test input
Turns the OSSD outputs ON or OFF, depending on the configuration.