Sezione generalità e caratteristiche tecniche
7
SECTION 1 GENERAL INSTRUCTIONS AND TECHNICAL
CHARACTERISTICS
In this section there will be general instructions to be followed for the installation and use
of gas fired convectors Calorio series, a short paragraph about the operation of the gas
convectors, their main characteristics and the technical data.
1.1 GENERAL INSTRUCTIONS
This manual is an integral and essential part of this product and must be given to the end
user.
This unit must be exclusively used for the purpose it was intended. Any other use is to be
considered improper and therefore dangerous.
The manufacturer cannot be held responsible for any damage resulting from incorrect
installation or failure to comply with the manufacturer’s instructions.
The unit must be installed respecting the internal laws.
Do not obstruct the intake air of the fan neither the outlet air grid.
)
In case of failure and/or bad/poor operation, stop the unit (shut off the gas supply)
do not attempt any repair or direct servicing. Call only
qualified service engineer
.
Any misapplication of the above instructions can compromise the safety of the unit.
To ensure the efficiency of the unit and its proper operation, it is essential that a qualified
service engineer carry out annual maintenance in accordance with the manufacturer’s
instructions.
Qualified service engineers are those having specific technical experience in
the installation of heating units for residential applications, designated by a local authority.
Should the unit be sold or transferred to another owner, ensure that the manual remains
with the unit for the use of the new owner and/or the installer.
Before starting the unit,
qualified personnel must check
:
- that the electrical and the gas supply ratings do exactly correspond to those
shown on the original rating plate.
- that the exhaust flue and the inlet air supply are properly installed.
- that the combustion air feed and exhaust are properly fitted in accordance with
the existing standards.
- the proper internal and external sealing of the combustion apparatus
- that fuel flow control is in accordance with the unit power requirements.
- that the unit is fed with the specific type of fuel for which it has been pre-set.