In this section you can find all the necessary instructions to install Calorio Series room
heaters from the hydraulic point of view.
3.1 GENERAL REQUIREMENTS FOR CALORIO SERIES
The installation shall be made, according to the Manufacturer’s instructions, by
qualified
service engineers
.
By
Qualified Service Engineers
we mean the personnel with specific technical
skills in the field of the heating system components. In any case, if you need more
information please contact the Pre-Sale Department of ROBUR S.p.A. (tel. +39
035/888111).
An incorrect installation can cause damages to people, animals and property. In case of
erroneous installation, the Manufacturer cannot be held responsible for such damages.
The installation must be performed in compliance with the existing European laws, rules
and regulations referred to gas and electrical appliances.
In particular it must be respected all related to the distance between the flue terminal and
windows, balconies, gutters, etc., and distances to the soil or to the sidewalk.
The terminal does not require any type of protection
.
For the correct installation is required to respect the following conditions:
-
The gas convector must be installed indoor on an external perimeter wall or closet
o it, respecting the distances indicated in Figura 1.
-
The minimum recommended distance from the basement is 8 cm (see Figura 1)
and possibly not superior to 35 cm because, for bigger height there will be a non
uniform distribution of the heat in the building.
-
Keep a minimum distance of 10 cm between the sides of the gas convector and
any type of object in order to permit the dismounting and re mounting of the panel.
-
If a bracket would be left on the unit, a space of 10 cm (at least) must be
considered.
-
Make sure that it exists an adequate furniture and network of gas.
-
Make sure that it exists an adequate connection to the electrical network (230V