![Robur Calorio Series Installation, Use And Maintenance Manual Download Page 27](http://html1.mh-extra.com/html/robur/calorio-series/calorio-series_installation-use-and-maintenance-manual_1471529027.webp)
Linea Calorio – Radiatori individuali a gas – Libretto d’installazione, uso e manutenzione
26
CONNECT THE CONVECTOR TO GAS NETWORK
1.
The connection to the gas network must be done with a rigid copper or steel pipe
and fittings; as alternative it could be also utilised a flexible stainless steel pipe.
2.
Connect the gas pipe to the nipple you find on the right bottom part of the gas
convector. (see ref. A of Figure 13 and Figure 14).
The connection to the gas pipe must be carefully sealed in order to grant the leak-
tightness by using a sealer according to the EN 751-1 and EN 751-2 law.
The connection must be realised without any tension to the pipe or to other
components of the unit.
)
Provide a shut-off cock on the gas network, in vertical position and easily
accessible, as required in the norms about gas installations.
Figure 13
– Positioning gas feed for model 52
Figure 14
– Positioning gas feed models 41, 42 and 51
A
A