background image

5

27/11/2020

    UNPACKING

• WARNING - some of the tools are very sharp e.g. 
blades, etc..

    INSTALLATION

• We recommend that you install your appliance on 
its wall frame. 

    CONNECTION

• Always check that your mains supply corresponds 
to that indicated on the identification plate on the 
motor unit and that it can withstand the amperage.
• Never plug your appliance into the mains supply 
before placing it inside the preparation bowl.

    HANDLING

• Always take care when handling the blades, as 
they are extremely sharp.

    ASSEMBLY PROCEDURES

• Follow the various assembly procedures carefully 
(see page 8) and make sure that all the attachments 
are correctly positioned.

    USE

• Never try to override the safety systems.
• Never insert an object into the preparation.
• Never switch the appliance on unless it has been 
placed in the preparation bowl.
• Before dismantling the foot, bell or whisk always 
check that the power mixer is unplugged.
• We recommend that you tilt the appliance at  
a slight angle to prevent the bell from touching the 
bottom of the container.

    CLEANING

• As a precaution, always unplug your appliance 

before cleaning it. 
• Always clean the appliance and its attachments at 

the end of each cycle.
• Never immerse the motor unit in water. 
• For parts made from aluminum, use cleaning fluids 

intended for aluminum.
• For plastic parts , do not use detergents that are 

too alkaline (e.g., containing too much caustic soda 

or ammonia).
• Robot-Coupe can in no way be held responsible for 

the user’s failure to follow the basic rules of cleaning 

and hygiene.

    MAINTENANCE

• Before opening the motor housing, it is absolutely 

vital to unplug the appliance.
• Check the seals and washers regularly and  ensure 

that the safety devices are in good working order.
• It is particularly important to maintain and check 

the attachments since certain ingredients contain 

corrosive agents, e.g. citric acid.
• Never operate the appliance if the power cord or 

plug has been damaged or if the appliance fails to 

work properly or has been damaged in any way.
• Do not hesitate to contact your local Maintenance 

Service if something appears to be wrong.

  W A R N I N G 

Procedure to follow if the stick blender is 

accidentally immersed during use.

1)  Do not touch either the power mixer, the 

bowl or the work surface.

2)  Unplug the mixer’s power cord from the 

wall socket.

3)  Remove the power mixer from the 

preparation.

4)  Tilt the power mixer to drain off as much  

liquid as possible.

5)  Do not switch the power mixer back on, as 

there is still a risk of electrocution.

6)  Send the power mixer to a Robot-Coupe 

approved after-sales service to have the 

electrical components cleaned and dried.

WARNING: In order to limit accidents such as electric shocks or personal injury, and in order to limit material damage due to misuse of the 

 appliance, please read these instructions carefully and follow them strictly. Reading the operating instructions will help you get to know your 

appliance and enable you to use the equipment correctly. Please read these instructions in their entirety and make sure that anyone else who 

may use the appliance also reads them beforehand. Our equipment is designed for professional use and must not be used by children under 

any circumstances.

IMPORTANT WARNING

W A R N I N G

KEEP THESE INSTRUCTIONS IN A SAFE PLACE

Summary of Contents for MP 350 Combi Ultra

Page 1: ...Ultra MP 600 Ultra MP 800 Turbo MP 350 Combi Ultra MP 450 Combi Ultra MP 450 FW Ultra MP 450 FW XL Ultra MP 350 Ultra MP 350 Combi Ultra MP 450 Combi Ultra MP 450 FW Ultra MP 450 FW XL Ultra MP 450 U...

Page 2: ...www robot coupe com Register your product on line...

Page 3: ...C Directive Low Voltage 2014 35 EU Directive Electromagnetic Compatibility 2014 30 EU Directive Reduction of Hazardous Substances in Electrical Equipment RoHS 2011 65 EU Directive Waste Electrical and...

Page 4: ...function Whisk function ASSEMBLING DISMANTLING Blade function Whisk function Mixing tool function USES EXAMPLES PAN SUPPORT Adjustable support Single support HYGIENE CLEANING Motor unit After each us...

Page 5: ...and or replacements for blades which have become blunt chipped or worn after a normal or excessive period of use 3 Materials or labour to replace or repair scratch ed stained chipped pitted dented or...

Page 6: ...re opening the motor housing it is absolutely vital to unplug the appliance Check the seals and washers regularly and ensure that the safety devices are in good working order It is particularly import...

Page 7: ...n extremely powerful motor they can process quantities of 50 litres to 400 litres according to the model Their rapidity and the quality of the finished product are beyond reproach In whisk function In...

Page 8: ...P 450 Combi Ultra models speed ranging from 160 to 510 rpm It is advisable to start at a low speed when using the whisk Principle of automatic speed regulation once you have selected the right speed l...

Page 9: ...into contact with the bottom of the recipient The power mixer can equally be rested against the rim of the container but must be tilted and the bell must not touch the bottom of the container 4 In thi...

Page 10: ...t C of the whisk holder into the aluminium casing Turn the whisk holder in the direction of the arrow see figure until it is locked into place moderately tightly Check that the machine is not plugged...

Page 11: ...he whisk holder in the opposite direction to that used when attaching it When it will go no further remove the whisk holder from the aluminium casing Fitting the whisks into the whisk holder Grasp the...

Page 12: ...pans diameter HYGIENE The equipment must be clean at all stages of production It is vital to clean the power mixer thoroughly between each job using a disinfectant detergent N B NEVER USE PURE BLEACH...

Page 13: ...lean with a throwaway wiper Never clean the whisk holder in a dishwasher WHISKS The whisks can be cleaned either by hand or in a dishwasher To ensure effective cleaning we advice you to remove the whi...

Page 14: ...ng tool C on the cartridge B Remove the cartridge from its place by knocking D on the knife dismantling tool C with a plastic mallet W A R N I N G From time to time check The state of the 3 buttons wa...

Page 15: ...30 V 50 Hz 1 500 to 9 000 2 3 120 V 60 Hz 1 500 to 9 000 4 5 220 V 60 Hz 1 500 to 9 000 2 2 Single phase machine MP 600 Ultra Single phase machine MP 800 Turbo Motor Speed rpm Intensity Amp 230 V 50 H...

Page 16: ...ugged the power mixer will not restart by itself It is necessary to follow the steps in the paragraph entitled OPERATING THE APPLIANCE page 6 Intensity Warning Light MP 600 Ultra and MP 800 Turbo In c...

Page 17: ...ity warning flashes for 5 seconds to inform you that the motor will stop shortly This stop indicates that the preparation in process is too thick or can not be made with a stick blender Light light MP...

Page 18: ...17 27 11 2020 TECHNICAL DATA...

Page 19: ...19 27 11 2020...

Page 20: ...21 27 11 2020...

Page 21: ...ennes Cedex France Tel 01 43 98 88 15 Email international robot coupe com Robot Coupe U K LTD Fleming Way Isleworth Middlesex TW7 6EU Tel 020 8232 1800 Email sales robotcoupe co uk Robot Coupe Austral...