Alarms list Ecoplat Plus FRD
In Ecoplat Plus FRD, the alarms are shown directly on the machine display, along with the code for the alarm itself.
Code
Problem
Cause
Solution
E02
Plate alarm
Emergency plate pressed
Release the emergency plate and
reset the machine
E31
Rotation motor alarm
Inverter overload
Remove the overload cause. Switch
the machine off and then on again
E32
Lifting motor alarm
Inverter overload
Remove the overload cause. Switch
the machine off and then on again
E60
Film breakage alarm
Film breakage detected during
a wrapping cycle
Re-join the film to the product and
reset the machine
E61
Table rotation alarm
A fault or an obstacle is
preventing the table from
moving
Remove the fault cause. Switch the
machine off and then on again
E64
Carriage lifting alarm
A fault or an obstacle is
preventing the film carriage
from moving
Remove the fault cause. Switch the
machine off and then on again
E69
Generic alarm
The maximum number of self-
learning mode steps has been
reached
Reset the machine. Repeat the self-
learning procedure
E74
Pallet start alarm
If the pallet is not present on
the machine, the machine will
remain in STOP mode when
CYCLE START is pressed
Position the product on the table and
start a new cycle
E83
HMI communication alarm
Electronic fault
Contact technical support
E83
Inverter communication alarm
Electronic fault
Contact technical support
E98
Carriage bypass alarm
Suspension of the emergency
due to the rotation of the key-
operated selector
Release the selector and reset the
machine