ENG
INFORMATION ABOUT THE USE
48
6.2. DESCRIPTION OF CONTROLS (ECOPLAT PLUS BASE)
A)
Emergency stop button:
it is used in case of imminent risk to stop, with a voluntary action, the machine parts which may pose a risk.
For further details, see the paragraph “description of safety devices”.
B)
“Cycle start” button
:
it is used to start the wrapping automatic cycle.
The button indicator light on indicates that the electrical power supply is activated.
C)
“Cycle stop” button
:
it is used to stop the wrapping automatic cycle.
D)
“Upper and lower wrapping” selector
:
used to set the number of wraps (upper and lower) to be performed on the pallet.
-
D0: no wrapping.
-
D1: one wrapping on the top and bottom.
-
D2: two wrappings on the top and bottom.
-
D3: reinforcing wrapping
When the selector is set to position “
D3
”, the film carriage stops to allow reinforcing wrapping to be performed.
As long as the selector remains in position “
D3
”, wrapping is performed in the same point.
Set the selector to one of the “
D0-D1-D2
” positions to restart the film carriage.
E)
Carriage "upstroke/downstroke speed” button:
used to set the film carriage upstroke and downstroke speed while the carriage is in motion.
-
Pressed on (E1), the button decreases film carriage speed.
-
Pressed on (E2), the button increases film carriage speed.
-
If either buttons (E1 - E2) are pressed together with button (C
), they move the film carriage (in “manual”
mode).
F)
“Table rotation speed” button:
used to set to table rotation speed, with the rotary table in motion.
-
Pressed on (F1), the button decreases table rotation speed.
-
Pressed on (F2), the button increases table rotation speed.
-
Pressing key (F2) together with button (C
) (Stop button) allows moving the table (in “manual mode”).
G)
“Reset” button
:
it is used to reset the machine before restarting it after an emergency stop or after a shut-down due to the
disconnection of the power supply.
H)
Emergency override key-operated switch:
it is used to temporarily bypass the carriage emergency.
When the key is turned to the “
I
” position (hold to run), the “start” button (
B
) lights up. When the “start” button
(B) is pressed, the carriage is raised.
J)
USB port:
used to update the machine software.
If a USB flash drive containing updated software is inserted into the port, the software will be installed on the
machine when it is turned on.
K)
Main disconnector:
it enables and disables the power supply.
-
Pos. “
O
”: power supply off.
-
Pos. “
I
”: power
supply on.