ENG
INFORMATION ABOUT THE USE
50
6.3. DESCRIPTION OF CONTROLS (ECOPLAT PLUS FRD)
A)
Emergency stop button:
it is used in case of imminent risk to stop, with a voluntary action, the machine parts which may pose a risk.
For further details, see the paragraph “description of safety devices”.
B)
“Cycle start” button
:
it is used to start the wrapping automatic cycle.
C)
“Cycle stop” button
:
it is used to stop the wrapping automatic cycle.
D)
Multi-function selector:
it allows activating and setting machine functions.
Turn the selector (clockwise or counter-clockwise) until the LED for the desired function turns on.
E)
Digital display:
it shows the working parameters and alarm codes.
F)
Machine functions:
-
F1-F8
: these are the various functions available on the machine (see the “Machine functions” section).
G)
“Reset” button
:
it is used to reset the machine before restarting it after an emergency stop or after a shut-down due to the
disconnection of the power supply.
H)
Emergency override key-operated switch:
it is used to temporarily bypass the carriage emergency.
When the key is turned to position “
I
” (hold to run), the user interface screen will display the page “emergency
override” and this allows the carriage alone
to be lifted by pressing the “multi
-
function selector” (
D).
J)
USB port:
used to update the machine software.
If a USB flash drive containing updated software is inserted into the port, the software will be installed on the
machine when it is turned on.
K)
Main disconnector:
it enables and disables the power supply.
-
Pos. “
O
”: power supply off.
-
Pos. “
I
”: power supply on.