Flue assembly - Mounting the hood body

• Position the upper chimney section and fix

the upper part to the frame using the 2 screws
(2,9 x 6,5) provided.

• Fit the lower chimney section onto the frame,

holding it in place until the hood body has been
fixed in place.

Recirculation version
• Make sure that the outlet of the extension

piece 14.1 is horizontally and vertically
aligned with the chimney outlet.

• If this is not the case, remove the lower

chimney section and adjust the position by
cutting the hood body extension 14 along
one of the thinner section channels denoting
the pre-fixed lengths, then reassemble as
described previously.

Before fixing the hood body to the frame:
• Remove the grease filters from the hood body.
• Remove any activated charcoal filters (if fitted).
• From below, use the 4 screws 12f (M6 x 10) provided

to fix the hood body to the frame.

• For the recirculation version, locate the directional

grill 8 in its housing. Ensure that it is inserted correctly
in connector 15

ELECTRICAL CONNECTION
• Connect the hood to the mains
• Connect the control connector Cmd.
• Place the connector in the junction

box 24 and close it using the 2 screws
12e (2,9 x 9,5) provided.

• Fix the junction box to the hood body

using the 2 screws 12c (2,9 x 6,5) provided.

• For the recirculation version, fit the activated

carbon filter.

• Replace the grease filters.

24

Upper frame
• Align the power supply cable feed hole

• Fix the upper frame to the ceiling or shelf using:

• For concrete ceilings, use the appropriate plugs for the screw size

(not provided).

• For hollow brick ceilings of wall thickness of approximately 20 mm:

use 4 plugs 11 and 4 screws 12h (5,2 x 70), provided.

• For wooden beam ceilings, use 4 wood screws (not provided).
• For wooden shelf, use 4 screws 12g (M6 x 80) with washers 22 and

nuts 23, provided.

Lower frame
• Fix the lower frame using the 8 previously removed screws, adjusting the

length according to the installation height (hood body lower fixing surface
must be at least 720 mm from the hob).

• For the recirculation version, turn the frame in the direction chosen for the

recirculated air outlet.

• The frame mountings must be secure to withstand the weight of the hood

and any stresses caused by the occasional side thrust applied to the
device. On completion, check that the base is stable, even if the frame is
subjected to bending.

• In all cases where the ceiling is not strong enough at the suspension point,

the installer must provide strengthening using suitable plates and backing
pieces anchored to the structurally sound parts.

Connections

DUCTED VERSION
When installing the ducted version,
connect the hood to the chimney
using either a flexible or rigid pipe
ø 150 or 120 mm, the choice of
which is left to the installer.

FIXING THE FRAME
Before fixing, separate chimney elements

2.1 - 2.2 from the frame, then separate the
two sections of the frame by unscrewing

the 8 side screws to obtain the Upper
frame and Lower frame.

RECIRCULATION VERSION
• To install a ø 120 mm air exhaust connection,

insert the reducer flange 9 on the hood body
outlet.

• Fix the pipe using the pipe clamps 25 provided.
•  Remove any activated charcoal filters.
•  Insert reducer flange 9 on the extractor outlet.

• Push fit the extension piece 14 onto the flange.
• Push fit connector 15 onto the extension piece.

• Insert extension piece/connector 14.1 laterally

on connector 15.

Summary of Contents for RIIC9PLUS

Page 1: ...9001 Certified email enquiries robinhood co nz for service of advice in Australia contact Robinhood Aus Pty Ltd A C N 079 616 550 P O Box 4189 Mulgrave Victoria 3170 TEL 1800 648 556 FAX 1800 628 577 email enquiries robinhood co nz RECOMMENDS UNIDUCT DUCTING SYSTEMS FOR RANGEHOODS 104629 Issue C ECN 07 007 P R O D U C T D I M E N S I O N S C A N O P Y I N S T A L L A T I O N I N S T R U C T I O N ...

Page 2: ...ed by children or persons not instructed in its correct use This appliance is not intended for use by young children or infirm persons without supervision MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Clean the hood using a damp cloth and a neutral liquid detergent This ...

Page 3: ...1a 7 1b INSTALLATION Drilling the Ceiling shelf and fixing the frame DRILLING THE CEILING SHELF Use a plumb line to mark the centre of the hob on the ceiling support shelf Place the drilling template 21 provided on the ceiling support shelf making sure that the template is in the correct position by lining up the axes of the template with those of the hob Mark the centres of the holes in the templ...

Page 4: ... brick ceilings of wall thickness of approximately 20 mm use 4 plugs 11 and 4 screws 12h 5 2 x 70 provided For wooden beam ceilings use 4 wood screws not provided For wooden shelf use 4 screws 12g M6 x 80 with washers 22 and nuts 23 provided Lower frame Fix the lower frame using the 8 previously removed screws adjusting the length according to the installation height hood body lower fixing surface...

Reviews: