Supplement
POH
DR400/120D,
DR400/140B,
DR400/180R, DR400/200R, DR400/RP
Issue 3
– July 2014
Page 3 - 7
b) Both FADEC Lamps are flashing
Note
:
The load display may not correspond to the current
value.
(1) Press FADEC-Test knob at least 2 seconds (refer to section 1
“FADEC Reset”)
(2) FADEC Lamps extinguished (LOW):
a) Continue flight normally,
b) Inform service center after landing.
(3) FADEC Lamps steady illuminated (HIGH):
a) Check the available engine power,
b) Expect engine failure.
c) Flight can be continued, however the pilot should
i) Select an airspeed below 100 KIAS (185 km/h)
ii) Land as soon as possible
iii) Be prepared for an emergency landing.
(4) Inform service center after landing.