FADEC malfunction in flight
Note
:
The
FADEC
consists
of
two
components
that are independent of each other: FADEC A and
FADEC B. In case of malfunctions in the active FADEC,
it automatically switches to the other.
a) One FADEC Lamp is flashing
(1) Press FADEC-Test knob at least 2 seconds
(2) FADEC Lamp extinguished (LOW category warning):
a) Continue flight normally
b) Inform service center after landing.
(3) FADEC Lamp steady illuminated (HIGH category warning):
a) Observe the other FADEC lamp,
b) Land as soon as practical,
c) Airspeed should be below 100 KIAS (185 km/h),
d) Inform service center after landing.