SECTION 13: CONTROL METHODS
There are se
v
eral methods of controlling CRVSF-
Series systems. The options are as follo
w
s:
13.1 ROBERTS GORDON
®
System Control
The System Control is an electronic control panel
designed to control CRVSF-Series heating systems.
The System Control
w
iring is sho
w
n
System Control Installation Man
u
al
(P/N 10091601NA).
The System Control can be
u
sed to control an EP-
100 or EP-201 p
u
mp from the control panel. Other
p
u
mps s
u
ch as the EP-301 and 3 Ø models may be
controlled in conj
u
nction
w
ith a relay or motor starter.
The System Control can control
u
p to fo
u
r zones of
b
u
rners and
u
p to t
w
o
v
ac
uu
m p
u
mps.
The electrical circ
u
it is a 120 Vac (20 A) s
u
pply.
The o
u
tp
u
t for the thermostat is 24 Vac.
A System Control operated system has t
w
o min
u
tes
post p
u
rge p
u
mp operation to completely exha
u
st
prod
u
cts of comb
u
stion from the system. A system
control pro
v
ides indication of po
w
er to the p
u
mp and
zones and indicates the stat
u
s of the press
u
re s
w
itch
w
ith lights.
The System Control is ETL listed in accordance
w
ith
UL873 – Standard for Temperat
u
re Indicating and
Reg
u
lating Eq
u
ipment.
13.2 ROBERTS GORDON
®
ULTRAVAC
™
(CRVSF-6/-
8
only)
The ROBERTS GORDON
®
ULTRAVAC
™
is a micro-
processor based control package designed for
mod
u
lating control of CRVSF-Series heaters based
on o
u
tdoor temperat
u
res. The controls offer f
u
ll
mod
u
lation bet
w
een 60% and 100% of system
maxim
u
m rated inp
u
t.
This controller is capable of gi
v
ing control o
u
tp
u
ts to
one p
u
mp and three heating zones. The controller
also feat
u
res inp
u
ts
w
hich are
u
sed for indoor and
o
u
tdoor signal condition monitoring.
System stat
u
s and settings are
v
ie
w
ed and altered
from a PC (not s
u
pplied) r
u
nning ROBERTS
GORDON
®
ULTRAVAC
™
Soft
w
are.
ROBERTS GORDON
®
ULTRAVAC
™
Soft
w
are
req
u
ires a PC (not s
u
pplied) r
u
nning Windo
w
s
®
95 or
higher,
w
ith a Penti
u
m
®
class processor and at least
64k of RAM. For complete installation details, please
refer to the ROBERTS GORDON
®
ULTRAVAC
™
Installation, Operation and Ser
v
ice Man
u
al (P/N
10081601NA), latest re
v
ision.
Special desi
g
n re
q
uirements apply for CRVSF-
Series systems usin
g
the ROBERTS GORDON
®
ULTRAVAC
™
Controller.
B
u
ildings today demand all sorts of control options
based on the
u
ser’s preference. ULTRAVAC™
controls offer a host of comm
u
nication options for
integration
w
ith controls’ net
w
orks to best ser
v
e
indi
v
id
u
al needs:
ULTRAVAC™ BMS Link:
Interface ULTRAVAC™
w
ith other b
u
ilding management control platforms
u
sing BACnet
®
or MODBUS
®
protocol
w
hich
comm
u
nicates
v
ia o
u
r ULTRAVAC™ BMS Link
option.
TCP/IP (LAN):
Connect to ULTRAVAC™
v
ia yo
u
r
local area net
w
ork of comp
u
ters. Load ULTRAVAC™
soft
w
are onto any comp
u
ter on the net
w
ork and
control and
v
ie
w
yo
u
r heating system from yo
u
r
comp
u
ter
v
ia static IP address.
MODEM:
Dial into ULTRAVAC™ from any
w
here in
the
w
orld
v
ia modem. S
u
pplied as standard on all
central controllers!
RS-4
8
5:
Hard
w
ire ULTRAVAC™ directly to yo
u
r
comp
u
ter.
13.3 CORAYVAC
®
Modulatin
g
Controls
For a ROBERTS GORDON
®
CORAYVAC
®
Mod
u
lating system, combine a mod
u
lating
thermostat, a thermostat relay (P/N 90417600K) and
DANGER
Electrical Shock Hazard
Disconnect electric before service or
maintenance.
More than one disconnect switch may be
required to disconnect electric to the unit.
Control must be properly grounded to an
electrical source.
Failure to follow these instructions can
result in death or electrical shock.
WARNING
Explosion Hazard
Turn off gas supply to heater before service.
Failure to follow these instructions can result
in death, injury or property damage.
Summary of Contents for CorayVac Classic SF Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 65: ...SECTION 14 STARTING THE SYSTEM 59 of 83 FIGURE 41 Vacuum Reading ...
Page 75: ...SECTION18 TROUBLESHOOTING 69 of 83 18 1 Troubleshooting Flow Chart ...
Page 76: ...CRVSF SERIES INSTALLATION OPERATION AND SERVICE MANUAL 70 of 83 Troubleshooting Flow Chart ...
Page 84: ...CRVSF SERIES INSTALLATION OPERATION AND SERVICE MANUAL 78 of 83 ...
Page 88: ...CRVSF SERIES INSTALLATION OPERATION AND SERVICE MANUAL 82 of 83 ...
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......