SECTION 21: GENERAL SPECIFICATIONS FOR PUMPS
* For starter, see National Electric Code (NEC) requirement for motors 1 hp or higher.
SECTION 22: GENERAL SPECIFICATIONS FOR AIR SUPPLY BLOWER
Capacity
240 CFM @ 0.75 in wc
Power (W)
167
Phase
1
Hertz (Hz)
60
Voltage (V)
120
Full Load Amp (Amps)
1.5
R.P.M.
3000
Motor Enclosure
OPEN FC
Inlet/Outlet (In.)
5/5
Weight (lbs.)
10
C
B
G
A
E
D
F
dia.
Model
EP-100
EP-201
EP-203
EP-301
EP-303
Horsepower (Hp)
1/3
3/4
3/4
2*
2*
Phase
(Ø)
1
1
3
1
3
Hertz (Hz)
60
60
60
60
60
Voltage (V)
115/230
115/230
208-230/460
208-230
208-230/460
Full Load Amp (Amps)
4.8/2.4
6.6/3.3
2.4-2.2/1.1
12.8-11.5
5.5-5.2/2.6
R.P.M.
3450
3450
3500
3450
3450
Motor Frame
56
56
56
90
90
Motor Enclosure
TENV
TENV
TEFC
TEFC
TEFC
Noise Level @ 5' (DBA)
-
70
70
-
-
Inlet/Outlet (In.)
4/4
4/4
4/4
6/6
6/6
Weight (lbs.)
62
112
112
170
170
Pump Dimensional Data (in.)
Model
A
B
C
D
E
F
G
EP-100
17
14.5
21
3.75
10
4
4
EP-201/203
17.75
17
20.25
3.25
10
4.5
4.5
EP-301/303
25.6
24.8
22.7
4.8
15.2
6
6
Summary of Contents for CorayVac Classic SF Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 65: ...SECTION 14 STARTING THE SYSTEM 59 of 83 FIGURE 41 Vacuum Reading ...
Page 75: ...SECTION18 TROUBLESHOOTING 69 of 83 18 1 Troubleshooting Flow Chart ...
Page 76: ...CRVSF SERIES INSTALLATION OPERATION AND SERVICE MANUAL 70 of 83 Troubleshooting Flow Chart ...
Page 84: ...CRVSF SERIES INSTALLATION OPERATION AND SERVICE MANUAL 78 of 83 ...
Page 88: ...CRVSF SERIES INSTALLATION OPERATION AND SERVICE MANUAL 82 of 83 ...
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......