Section A - 7
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
TECHNICAL FILE
1200W HMI FOLLOW SPOTS
1149 & 1449 /
B, C & CB
PLACING THE LAMP.
User's precautions:
- Disconnect from the mains.
- Lamp is cold.
- Avoid touching the bulb of the lamp.
- Open the bonnet and the side trapdoors of the lamp house.
- Use only when lamp is in place
Preparing the lamp:
- Unscrew the nuts 1 without completely taking them off.
INSTALLING THE LAMP :
- Place the lamp into the contacts 2 and
the tip-off in the upper postion D .
- Tighten the nuts 1 firmly, by hand.
Warning : A bad lamp tightening can cause
a bad contact and a defective
ignition. Check regularly that the
nuts 1 are well tightened.
Lamp.
Warning : Do not use a lamp, if the diameter
of the bulb is greater than Ø28mm.
SWITCHING ON.
- No matter what the position of the circuit breaker is 3 , make sure
that the mains checklight 4 is ON.
- Engage the circuit breaker 3 and the automatic breaker 5 .
Control mode - 2 choices:
1 - the "ON / OFF" switch 6 .
2 - an external switch on relay contact (1A - 250V), connected
between two pins on the connector 7 .
! IMPORTANT :
The priority between 6 and 7 is always the ignition - switching OFF
is only possible if 6 and 7 are OFF.
Warning :
Carry out the connections before
connecting to the mains ( refer to section A - 5).
Ø28 maxi
180
1
2
2
1
A
B
C
E
D
A
B
C
D E
Disconnect from the mains before any servicing.
Service only by qualified technician.
Summary of Contents for Lucy 1449
Page 2: ...ii NOTES...