Section A - 5
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
TECHNICAL FILE
1200W HMI FOLLOW SPOTS
1149 & 1449 /
B, C & CB
Power supply unit
(P.S.U.)
A
B
C
CONNECTIONS.
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 11 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lighting unit's power cable B by passing it
inside the yoke.
- Leave a little slack and then block the cable B into the lock d .
- Place the lamp into position - refer to section A - 7.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lamp house's bonnet when the
lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when the lamp is in place.
DESCRIPTION.
A
1200W Hot restrike follow spot.
B Lighting unit's power cable.
Cable 7x4AWG 19G 12mm
2
, length 3m equipped
with 16 x 16A male HARTING connector.
C Power
supply
unit.
1 - EF HARTING 16 x 16A - 2 latch connector.
2 - Mains cable.
3 - Time meter.
4 - General 16A circuit breaker (208/245V).
- General 25A circuit breaker (
110V).
5 - Mains, checklight.
6 - 1A automatic breaker.
7 - "ON/OFF" switch.
8 - "Wieland" 2 point connector : remote control.
9 - Lamp ON, checklight.
If the lamp's checklight is OFF when the switch is
ON; the lighting of the lamp has failed.
Repeat the operation - refer to section A - 7.
10 & 11 - Rating plate.
d
0 - OFF
0 - OFF
30.23
LAMP ON
ON
TELECOMMANDE /
REMOTE CONTROL
AMONT
MAINS
FUSE
OFF
3
8
9
1
10
11
7
5
6
4
2
C
HMI 1200
220/240V 50Hz
0 - OFF
Make sure the fan is working correctly
when switching on the unit.
Summary of Contents for Lucy 1449