7. Putting the machine into operation
47
7.5
Stopping the engine
See also manual of engine manufacturer.
NOTICE
Risk of engine damage!
The engine may be damaged if it is suddenly stopped when
running at high speed.
►
Before shutting down the engine after running at high
speed and full power, reduce the engine speed and let
the engine run on idle for about a minute.
Also let the engine run at idle speed for about
a minute to allow it to cool down
1.
Switch off the working machine (main switch in OFF posi-
tion).
2.
Move engine switch to the „OFF“ Position.
Fig. 45: Engine switch in Position
“OFF”
1
Position
“OFF”
2
Engine switch
The engine stops.
3.
Move the fuel tap to the “
OFF
”
Position.