8. Maintenance
66
8.3.3
Mount the sealing washers with correct pretension
The sealing washers must be compressed with
the appropriate pretension, see illustration
below. The screw connection will not be a tight
seal if the pretension is too low or too high,
and there is a risk of it loosening.
Use medium-strength Loctite thread locker.
Fig. 58: Left: too little pretension, centre: too much pretension, right: optimum pretension
Fig. 59: Self-retaining nuts on the heat sink
Do not use Loctite where screws have self-
retaining nuts on the inside.
1.
Coat the threads of the screws with medium-strength Loc-
tite thread locker.
2.
Insert the heat sink screws and sealing washers and tight-
en to the correct pretension.
Mounting the heat sink