Default IP Address
-Preset IP address, you can set up only first byte of IP address
(2 or 10) e.g.
002
.019.052.086.
Custom IP Address
- The option enables to set up all bytes of IP address.
Net Mask
- The option enables to set up all bytes of Net Mask.
ArtNet Universe
- Use
this item to set a Universe (0-255). The Universe is a single DMX
512 frame
of 512 channels.
MANet Settings
- Use this menu to set parameters for MANet operation.
MANet Universe I/II
- The value of this item can be set in range 1-256.
MANet Session ID
- The value of this item can be set in range 1-32.
sACN Settings
- Use this menu to set parameters for sACN operation.
sACN Universe
- The value of this item can be set in range 1-32000.
sACN Priority
- The value of this item can be set in range 0-255.
Klingnet Settings
- Use this menu to enable or disable Klingnet protocol.
7.2 Tab "Information"
Fixture Times
- The menu provides readouts of fixture operation hours and air filters using hours.
Power On Time Hours
- Select this menu to read the number of fixture operation hours.
Total Hours
-
The item shows the total number of the operation hours since the
Robin Tarrantula TW has been fabricated.
Resetable Hours
-
The item shows the number of the operation hours that the
Robin Tarrantula has been powered on since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"
Air Filters
- Regular cleaning of the air filters is very important for the fixture´s life and performance.
Bild-up of dust, dirt and fog fluid residues reduces the fixture´s light output and cooling ability.
The two items of this menu help you to keep cleaning period of the air filters.
Alert period
- Cleaning schedule for the fixture depends on the operating environment.
It is therefore impossible to specify accurate cleaning interval. This item allows
you to change the cleaning interval of the air filters. This "alert" value is 300 hours and it
is set as default. Inspect the fixture within its 300 hours of operation to see whether cleaning
is necessary. If cleaning is required, clean all air filters and change the value in this menu
on acceptable level. Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time
- The item allows you to read the time which remains to cleaning air filters.
The time period is set in the menu mentioned above.
Expired time period is signalled by a negative mark (-) at the time value and a warning icon
on the display.
Clean the filters and reset this menu item (by touching the text box next to the item
"Elapsed Time").
Fixture Temperatures
- The menu is used to view temperatures of the fixture´s inside.
LEDs temperatures
- The menu shows temperature on the LEDs PCB .
Cur.
- A current temperature of the LEDs PCB.
Max.
- A maximum temperature of the LEDs PCB since the fixture has
been fabricated.
Max. Res.
- A maximum temperature of the LEDs PCB since the counter
was last reset.
In order to reset some counter to 0, touch desired text box under item "Max.Res."
Base Temperature
- The menu shows temperature in the fixture base (on the display PCB).
Current
- A current temperature in the fixture base.
Maximum NonRes.
- A maximum temperature in the fixture base since the fixture has
been fabricated.
Maximum Res.
- A maximum temperature in the fixture base since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."