14. Maintenance and cleaning
DANGER !
Disconnect from the mains before starting any
maintenance work
Important! Never use alcohols (ethanol, methanol, isopropyl alcohol), acetone and
another aggressive solvents for cleaning the optical parts of the fixture.
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
Use low-pressure compressed air to remove coarse dust from optical components.
Use distilled water with weak detergent solution and lint-free small cloth for further cleaning of front glass.
The cooling fans should be cleaned according to the situation (at least annually).
The interior of the base should be cleaned at least annually using a vacuum-cleaner or an air-jet.
More complicated maintenance and service operations are only to be carried out by authorized distributors.
Important! Check the air filters periodically and clean before
it become clogged!
Clean air filters placed in both covers of the head and one in the fixture base. The filters in head covers are
fastened by means of velcro fastener and the filter in the base is placed under a grille, which is fastened by
means of two magnets.
Use a vacuum cleaner, compressed air or you can wash them and put back dry.
After replacing the air filters, set the remaining time counter in the menu "Fixture Information" (Fixture Informa
-
tion--->Fixture Times--->Resettable Times--->Air Filt. Remains).