Robin CycBar 15
6
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulations.
If you install a cord cap on the power cable to allow connection to power outlets, install a grounding-type (earthed)
plug, following the plug manufacturer’s instructions.
The cores in the power cable are coloured according to the following table
.
Core (Eu)
Core (US)
Connection
Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green
Green
Earth
, GND,PE
This device falls under class one and must be grounded!
Design of the Robin CycBar 15 allows to connect several fixtures to AC mains power in one interconnected daisy
chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter
“Technical specifications “
The max. number of connected fixtures depends on the AC mains power voltage and fixture version:
EU version (CE)
US version (ETL)
15 fixtures at power supply= 230V
9 fixtures at power supply= 230V
13 fixtures at power supply= 208V
7 fixtures at power supply= 208V
7 fixtures at power supply= 120V
4 fixtures at power supply= 120V
Actual numbers of fixtures may differ from values stated above as you have to take into account the length of
supply cables, circuit breaker etc. at projecting of the fixtures installation.
Do not overload the supply line and the connecting leads.
Wiring and connection work must be carried out by qualified staff!
3.3 DMX 512 connection
The fixture is equipped with 5-pin XLR connectors for DMX input/output. Only use a shielded twisted-pair cable
designed for RS-485 5-pin XLR- connectors in order to connect the controller with the fixture or one fixture with
another.
Wiring of the XLR connectors:
DMX input
DMX output
XLR socket:
XLR plug
1
– Shield
2
- Signal (-)
3
- Signal (+)
4
– Not connected
5
– Not connected
To build a DMX chain
1.
Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain.
2.
Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture.
3.
Always connect the DMX output with the input of the next fixture until all fixtures are connected.
Do not overload the link. Max. 32 fixtures may be connected on a DMX link.