Robin CycBar 15
17
Note: If you do not want to continue in the software update, you have to switch off and on the fixture to
escape from the updating mode. We recommend to cancel all running programs on your computer before
starting the software update.
5. Double-click the software uploader file (e.g. DSU_RobinCycBar15_17010625.exe) in the extracted files.
The Software Uploader program will start running.
6. Select correct "COM " number if you use a Flash cable RS232/DMX or select "Robe Universal Interface " if you
use the Robe Universal Interface/Robe Universal Interface WTX and then click on the "Connect" button.
7. If the connection is OK, click the “Start Uploading" button to start software uploading. It will take several
minutes to perform software update.
If the option "Incremental Update" is not checked, all processors will be updated (including processors with the
same software version).
If you wish to update only processors with not topical versions of software, check the “Incremental Update box“.
Avoid interrupting the process. Update status is being displayed in the "Info Box" window. When the update is
finished, the line with the text “The fixture is successfully updated“ will appear in this window.
In case upload process is interrupted (e.g. power loss), the fixture stays in “Updating mode” and you will have to
repeat the software update again.
Another way, how to update software in the fixtures (especially large installation of fixtures) is to use the ROBE
Uploader. It is a software for automatized software update of Robe and Anolis fixtures. It can take advantage of
Ethernet ports and RDM support if present in the units. For more information please see
https://www.robe.cz/robe-uploader/.
7. Error and information messages
S.1.Er (Short 1 Error)
The message informs you that a right current was not measured in the first group of three LEDs. Some LED maybe does not
light or flashes.
S.2.Er (Short 2 Error)
The message informs you that a right current was not measured in the second group of three LEDs. Some LED maybe does not
light or flashes.
S.3.Er (Short 3 Error)
The message informs you that a right current was not measured in the third group of three LEDs. Some LED maybe does not
light or flashes.
S.4.Er (Short 4 Error)
The message informs you that a right current was not measured in the fourth group of three LEDs. Some LED maybe does not
light or flashes.
S.5.Er (Short 5 Error)
The message informs you that a right current was not measured in the fifth group of three LEDs. Some LED maybe does not
light or flashes.