background image

REDWash

 

3•192

 

 

4

 

 

Do

 

not

 

shake

 

the

 

fixture.

 

Avoid

 

brute

 

force

 

when

 

installing

 

or

 

operating

 

the

 

fixture.

 

 

This

 

fixture

 

was

 

designed

 

for

 

indoor

 

use

 

only,

 

do

 

not

 

expose

 

this

 

unit

 

to

 

rain

 

or

 

use

 

near

 

water.

 

 

When

 

choosing

 

the

 

installation

 

spot,

 

please

 

make

 

sure

 

that

 

the

 

fixture

 

is

 

not

 

exposed

 

to

 

extreme

 

heat,

 

moisture

 

or

 

dust.

 

 

Air

 

vents

 

and

 

slots

 

in

 

the

 

fixture´s

 

head

 

and

 

base

 

are

 

provided

 

for

 

ventilation,

 

to

 

ensure

 

reliable

 

operation

 

of

 

the

 

device

 

and

 

to

 

protect

 

it

 

from

 

overheating.

 

 

The

 

openings

 

should

 

never

 

be

 

covered

 

with

 

cloth

 

or

 

other

 

materials,

 

and

 

never

 

must

 

be

 

blocked.

 

 

This

 

fixture

 

should

 

not

 

be

 

placed

 

in

 

a

 

built

in

 

installation

 

unless

 

proper

 

ventilation

 

is

 

provided.

 

 

Only

 

operate

 

the

 

fixture

 

after

 

having

 

checked

 

that

 

the

 

housing

 

is

 

firmly

 

closed

 

and

 

all

 

screws

 

are

 

tightly

 

fastened.

 

 

Always

 

use

 

a

 

secondary

 

safety

 

cable

 

when

 

mounting

 

this

 

fixture.

 

 

Make

 

sure

 

that

 

the

 

area

 

below

 

the

 

installation

 

place

 

is

 

blocked

 

when

 

rigging,

 

derigging

 

or

 

servicing

 

the

 

fixture.

 

 

Do

 

not

 

block

 

the

 

front

 

objective

 

LEDs

 

with

 

any

 

object

 

when

 

the

 

fixture

 

is

 

under

 

operation.

 

 

The

 

fixture

 

becomes

 

very

 

hot

 

during

 

operation.

 

Allow

 

the

 

fixture

 

to

 

cool

 

approximately

 

20

 

minutes

 

prior

 

to

 

manipulate

 

with

 

it.

 

 

Operate

 

the

 

fixture

 

only

 

after

 

having

 

familiarized

 

with

 

its

 

functions.

 

Do

 

not

 

permit

 

operation

 

by

 

persons

 

not

 

qualified

 

for

 

operating

 

the

 

fixture.

 

Most

 

damages

 

are

 

the

 

result

 

of

 

unprofessional

 

operation!

 

 

Please

 

use

 

the

 

original

 

packaging

 

if

 

the

 

fixture

 

is

 

to

 

be

 

transported.

 

 

Please

 

consider

 

that

 

unauthorized

 

modifications

 

on

 

the

 

fixture

 

are

 

forbidden

 

due

 

to

 

safety

 

reasons!

 

 

If

 

this

 

device

 

will

 

be

 

operated

 

in

 

any

 

way

 

different

 

to

 

the

 

one

 

described

 

in

 

this

 

manual,

 

the

 

product

 

may

 

suffer

 

damages

 

and

 

the

 

guarantee

 

becomes

 

void.

 

Furthermore,

 

any

 

other

 

operation

 

may

 

lead

 

to

 

dangers

 

like

 

short

circuit,

 

burns,

 

electric

 

shock,

  

crash

 

etc.

 

 
 
 
 

Release the pan and tilt locks before operating the fixture. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for redwash 3-192

Page 1: ...Version 1 4 ...

Page 2: ...Wash 3 192 DMX protocol 11 5 Control menu map 14 6 Fixture menu 16 6 1 Fixture Address 16 6 2 Fixture information 17 6 3 Personality 18 6 4 Test sequences 19 6 5 Manual mode 19 6 6 Stand alone setting 19 6 7 Reset function 20 6 8 Special Functions 20 7 Power down mode 22 8 RDM 23 9 Error and information messages 24 10 Technical specifications 25 11 Cleaning and maintenance 27 11 1 Replacing the ma...

Page 3: ...e of the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Make sure that the power switch is set to off position before you connect the fixture to the mains The power plug has to be accessible after installing the fixture Do not overload wall outlets and extensi...

Page 4: ...ting this fixture Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Do not block the front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to cool approximately 20 minutes prior to manipulate with it Operate the fixture only after having familiarized with...

Page 5: ...t panel 8 Pan lock 9 Holder Front panel of fixture base 1 LCD display 2 RNS rotary wheel 3 Escape button 4 Enter button Rear panel of the fixture base 1 Power switch 2 Main fuse 3 Power cord 4 DMX output 5 pin XLR 5 DMX input 5 pin XLR 6 DMX output 3 pin XLR 7 DMX input 3 pin XLR 8 Ethernet input RJ 45 ...

Page 6: ...orking places and other endangered areas is forbidden For overhead use always install a safety rope that can hold at least 10 times the weight of the fixture You must only use safety ropes with screw on carbines Pull the safety rope through the two apertures on the bottom of the base and over the trussing system etc Insert the end in the carbine and tighten the fixation screw Rigging the fixture v...

Page 7: ... that the lens module locks 2 are properly locked 6 Shift the security lock 1 to the locked position red mark to secure the lens module in the placing Ensure the security lock is in the locked position RED mark before starting the fixture operation t is possible to install a plastic film to the glass holder module in order to get frost light 1 Uninstall the 25 lens array module 1 as described abov...

Page 8: ...troller with the fixture or one fixture with another Wiring of the XLR connectors DMX output DMX input XLR mounting sockets rear view XLR mounting plugs rear view 1 Shield 2 Signal 3 Signal 4 Not connected 5 Not connected To build a DMX chain 1 Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain 2 Connect the DMX output of the first fixture in...

Page 9: ...wisted wire pairs and standard RJ 45 plugs in order to connect the fixture to the network RJ 45 socket front view RJ 45 plug front view 1 TD 5 Not connected 2 TD 6 RX 3 RX 7 Not connected 4 Not connected 8 Not connected Patch cables that connect fixtures to the hubs or LAN sockets are wired 1 1 that is pins with the same numbers are connected together 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 If only the fi...

Page 10: ...et DMX has to be selected from the Set Ethernet Mode menu on the first fixture connected to the network Next fixtures have standard DMX addressing Caution At the last fixture the DMX clink has to be terminated with a terminator Solder a 120 Ohm resistor between Signal and Signal into a XLR plug and connect it to the DMX output of the last fixture Example ...

Page 11: ...le small large Figure of triangle small large Figure of five pointed star small large Figure of cross small large proportional proportional proportional proportional proportional proportional proportional 7 7 7 0 1 127 128 129 130 255 Pan Tilt Macro Speed Set pan tilt speed channel 5 at 0 DMX No macro generation Macro generation fast slow forwards No macro generation Macro generation slow fast bac...

Page 12: ... saturation control 0 100 proportional 15 11 19 0 255 Blue LEDs Array 2 Blue LEDs saturation control 0 100 proportional 16 12 20 0 255 White LEDs Array 2 White LEDs saturation control 0 100 Proportional 17 13 21 0 255 Red LEDs Array 3 Red LEDs saturation control 0 100 proportional 18 14 22 0 255 Green LEDs Array 3 Green LEDs saturation control 0 100 proportional 19 15 23 0 255 Blue LEDs 3 Array 3 ...

Page 13: ...5 Macro 26 Macro 27 Macro 28 Macro 29 Macro 30 Macro 31 step step step step step step step step step step step step step step step step step step step step step step step step step 26 22 14 10 0 31 32 63 64 95 96 127 128 143 144 159 160 191 192 223 224 255 Shutter Strobe Shutter closed Shutter open Strobe effect slow fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequenc...

Page 14: ...ime Fixture temperature Current Head Temp LEDs Temp Max Nonresetable Head Temp LEDs Temp Maximum Resettable Head Temp LEDS Temp DMX Values Pan 0 255 Dimmer Fine 0 255 Software Version IC1 B IC2 B IC1 H IC1 DS IC2 DS Product Ids Mac Adr RDM UID Personality User Mode User A Settings User B Settings User C Settings DMX Preset Mode 1 Ch 1 Pan Ch 28 Dimmer fine Set Active Mode 2 Ch 1 Pan Ch 24 Dimmer f...

Page 15: ...un Test Program Mode 2 Manual Mode Preset Effect Control Pan Position 1 7 Dimmer Position 1 6 Manual Effect Control Pan 0 255 Dimmer Fine 0 255 Stand alone Setting Music Trigger On Off Preset Playback Disabled Test program Program 1 Program 3 Playing Program Test Program in Loop Program 1 in Loop Program 3 in Loop Editing Program Program 1 Edit Steps Step 1 Pan 0 255 Program 3 Step 99 Dimmer Fine ...

Page 16: ...hernet Mode use the menu to set an Ethernet functional mode Disable Ethernet Disables an Ethernet operation Ethernet control data is received to the Ethernet input of the fixture RJ45 socket Each of fixtures has to be connected to Ethernet Ethernet DMX control data is received to the Ethernet input of the fixture goes throw the fixture to its DMX output fixture works as an Ethernet DMX converter I...

Page 17: ...od is 10 hours max is 300 hours Elapsed Time the option allows you to read the time which remains to cleaning air filters The time period is set in the menu mentioned above Expired time period is signalized by a negative mark at the time value and a warning icon triangle on the display with the following message Clean Air Filters Clean the filters and reset this menu item by pressing the ENTER but...

Page 18: ... to turn it off automatically 2 minutes after last pressing any button on the control panel Display Intensity select this function to adjust the display intensity 1 min 10 max Display Backlight select this function to adjust the display backlight 1 min 10 max Display Turned select this function to turn the display by 180 Blackout d M C This function enables to close a light output while the moving...

Page 19: ...lour the Green Balance 9 Repeat steps 6 7 for this channel 10 Use the RNS rotary wheel to select the last colour the Blue balance and repeat steps 6 7 for this colour LEDs Output Power The menu allows to choose 2 different operating modes for fixture s LEDs Maximum Max light output Maximum light output Note in this mode the total lumen maintenance is 70 at 10 000 hours Economical The light output ...

Page 20: ...the Stand alone setting menu and press the ENTER button 2 Use the RNS rotary wheel to select the Editing Program menu and press the ENTER button 3 Select the program you want to edit Program 1 Program 3 and press the ENTER button 4 Select the Edit Steps menu and press ENTER 5 Select the desired program step Step 01 Step 99 and press the ENTER button 6 Now you can edit DMX values for selected items...

Page 21: ...e_Uploader on your hard disk and download the software to it 3 Unpack the program from the archive If the Robe fixture is produced in both magnetic and electronic ballast version name of DMX Software Uploader is the same for both versions II Fixture software updating 1 Determine which of your ports is available on your PC and connect it with the DMX input of the fixture if you using the flash cabl...

Page 22: ...e finishing software upload After switching again the fixture on the fixture is still in the updating mode and the display is dark Restart the Software Uploader program and repeat software update from your PC 7 Power down mode This mode omits fixture reset after switching it on and reduces the power of motors The Power down mode is useful in special cases e g if the fixture is in a flight case and...

Page 23: ...ows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands for the REDWash 3 192 is the following Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_V...

Page 24: ...pping motor is defective or its driving IC on the PCB The yoke is not located in the default position after the reset of the fixture Tilt Error 1 Tilt Error 2 This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor failed or magnet is missing or the stepping motor is defective or its driving IC on the PCB The head is not located in the de...

Page 25: ... graphic LCD display and ROBE navigation system Control USITT DMX 512 RDM support Art Net protocol ready for ACN DMX protocol modes 5 8 16 24 or 28 control channels Control options DMX Auto trigger Audio trigger Operations modes DMX Stand alone Manual control of all effects via control panel Strobe Strobe effect with variable speed max 20 flashes per sec Pre programmed random strobe pulse effects ...

Page 26: ...power all LEDs at max intensity ambient temperature 20 C 68 F Dimensions mm Weight 22 kg 48 5lbs Included items 1 x REDWash 3 192 1 x Lens module 25 No 99012301 installed in the fixture 1 x glass holder for frost filters No 10980055 1 x grid module No 17040456 2 x Mounting bracket Omega CL assembled 1 x User manual Optional accessories Flash cable RS232 DMX No 13050624 Remote control IR No 1305041...

Page 27: ...tenance and service operations are only to be carried out by authorized distributors 11 1 Replacing the main fuse Only replace the fuse by the one of the same type and rating To replace the fuse 1 Disconnect the fixture from mains 2 Unscrew the fuse holder on the rear panel of the base with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the fuse holder 4 Install t...

Reviews: