7
4.Installation
4.1Fitting/Exchanging the lamp
DANGER !
Unplug from mains before !
Allow the lamp to cool for 20 minutes before removing the lamp cover
To insert the lamp MSD 250 open the small cover at the rear of the projection-head (see the drawing ) by
loosening the 4 screws on the cover.Remove the rubber seal.Loose the 4 screws ("V,X,Y,Z") on the lamp
assembly and gently pull the lamp assembly out.If changing the lamp, remove the old lamp from the socket.
Insert the lamp to the socket.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed
for.
Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer‘s notes!
Do not touch the glass bulb with bare hands during the installation! Make sure that the lamp is installed tightly
into the lampholder system.
Reinsert the lamp assembly and tighten the 4 screws ("V,X,Y,Z").Close the small lamp cover with the seal by
cross-tighten the 4 fastening screws with a torque of 6-7Nm..
Before striking the lamp, reset the "LAti/rSEt" and "LASt/rSEt"- counter in the "InFO" menu of the fixture, by
pressing the "Up" and "Down" buttons in one time and then confirming with the "Enter"-button on the remote
control.
Do not operate this fixture with opened housing-cover!
4.2Lamp adjustment
The fixture lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may improve
light performance.
Open the lamp cover at the rear of the projection-head by loosening the 4 screws on the cover.
Remove the rubber seal.
Lamp assembly
Lamp cover
Lamp
Rubber seal