10
4.6 Changing the power supply settings
Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency.
The wrong settings can cause poor performance or demage of the moving head.The factory settings are printed
on the bottom of the base.
If you want to change the power supply settings,follow the instructions:
1.Disconnect the fixture from AC power.
2.Open the plate cover of the base by loosening the 12 screws and remove the rubber seal.
3.Move the wire 1 on the transformer connection block to the position according to the desired voltage.
4.Move the wire 2 on the ballast connection block to the position according to the desired frequency
(voltage).
5.Close the base before applying AC power.To ensure a weather-tight seal when replacing the plate cover of
the base,carefully cross-tighten all screws with a torque of 6-7 Nm.
Examples:
EU-version
US-version
Summary of Contents for ECOLOR 250 XT
Page 1: ......