17
The master fixture starts simultaneous program start in the other slave fixtures.All fixtures have a definite,
synchronized starting point when playing back their programs.The number of running program is the same in all
slaves and depends on the master's choice (menu "St.AL." ).Every fixture runs its program repeatedly ,starting
the program step No.1 when requested by the master .
For example:
If the slave fixture has a shorter program length, it will continously repeat its program until the master fixture
finishes its own program and restarts its program running (slave 1- prog.step 3 will not be finished).
If the slave fixture has a longer program length, it will restart at prog. step 1 before it completes all its
prog.steps
(slave 2 - prog.step 5 will not be played)- see the picture bellow.
Stand-alone operation can be set for one or two periods during a 24 hour period,using the built-in clock or for a light
level,using the built-in light sensor.If both the clock and the light sensor are active, operation starts within the set
times or if it is darker than the light-level setting.Operation stops at the stop times or if that the ambient light is
brighter than the set light level.
If the time periods overlap each other or if the time period overlaps the light level period,the fixture will respond
to the events according to their rank.
For example:
The played program is the same for all time(light level) periods.
From the master's control panel is possible to control any slave in a master/slave chain.
Note:Disconect the fixtures from the DMX controller before master/slave operating ,otherwise data collisions can
occur and the fixtures will not work properly!
Note:It’s necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master fixture and into
the output of the last slave fixture in the data link in order to ensure proper transmission on the data link.
Starting point
Restart
All events will be executed
(Start1,Stop1,Start2,Stop 2).
The events Start 1 and Stop 2
will be executed only.
The events Start 1 and Stop
will be executed only.
The Time period1 and Light
period will be executed ,the
Time period 2 is eliminated.