11. Cleaning and maintenance 

 
 

DANGER ! 

Disconnect from the mains before starting any cleaning or maintenance work 

 
 
Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, non-
abrasive  washing detergent. Rinse it. 
There are no serviceable parts inside the device. 
 Maintenance and service operations are only to be carried out by a qualified person. 
Should you need any spare parts, please use genuine parts. 
 
If the power supply cable of this device will be damaged (cable firmly connected with the device), it has to be 
replaced by authorized distributors only in order to avoid hazards. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications are subject to change without notice. 

June 2, 2011 

Summary of Contents for CitySkape Xtreme

Page 1: ...Version 2 2 ...

Page 2: ...DMX 512 connection 8 3 6 Master slave connection 8 3 6 Stand alone operation 8 4 CitySkape Xtreme RGBCW DMX protocol 10 5 Control menu map 12 6 Fixture menu 14 6 1 Fixture Address 15 6 2 Fixture information 15 6 3 Personality 16 6 4 Manual mode 17 6 5 Test sequences 17 6 6 Stand alone setting 17 6 7 Special functions 18 7 RDM 20 8 Error and information messages 21 9 Wireless DMX operation 21 10 Te...

Page 3: ...ture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power data cord is never crimped or damaged by sharp edges Check the fixture and the power data cord from time to time Do not install the unit near naked flames During the operation the housing becomes hot u...

Page 4: ...o manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the result of unprofessional operation Do not attempt to dismantle or modify the unit Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please use the original packagin...

Page 5: ...loor or can be rigged on the structure via two omega holders in the following positions For securing of the fixture on a flat surface in the position B serves two mounting slots of diameter 8 5mm in the fixture base The four mounting holes of diameter 17mm are intended for permanent installation on the flat surface especially in position C Enhanced care has to be considered during the installation...

Page 6: ...ructural rigger Improper installation can result in bodily injury or damage to property For overhead use always install a safety rope that can hold at least 10 times the weight of the fixture You must only use safety rope with screw on carbine Pull the safety rope through the apertures in the fixture base and over the trussing system Caution Fixtures may cause severe injuries when crashing down If...

Page 7: ...e fixture Never close the barn doors during fixture operation 3 4 Changing the beam angle If you need to get a wide beam angle 25 you have to install frost glasses to both LED modules Before installing the frost glasses disconnect the fixture from the mains 1 Unscrew the ten countersunk screws 1 from the LED module 3 2 Lift the frame 2 with the gasket strip and carefully remove the clear glass 5 f...

Page 8: ...aster fixture and the output of the last slave with a 120 Ohm resistor in order to ensure the proper transmission on the data link 3 6 Stand alone operation The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be appli...

Page 9: ...CitySkape Xtreme RGBW 9 Note Disconnect the fixtures from the DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly ...

Page 10: ... LEDs LED module 2 Red LEDs saturation control 0 100 proportional 6 6 0 255 Green LEDs LED module 2 Green LEDs saturation control 0 100 proportional 7 7 0 255 Blue LEDs LED module 2 Blue LEDs saturation control 0 100 proportional 8 8 0 255 White LEDs LED module 2 White LEDs saturation control 0 100 proportional 1 5 9 0 1 15 16 17 55 56 57 95 96 97 134 135 136 174 175 176 214 215 Colour macros 255 ...

Page 11: ...osed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open Random strobe effects from slow to fast Shutter open step step proportional step proportional proportional step proportional step 2 7 11 0 255 Dimmer both LED modules Dimmer intensity from 0 to 100 proportional 8 12 0 255 Dimmer fine both LED modul...

Page 12: ...nu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti totL totL rSEt rSEt DM In rEd1 0 255 F dim 0 255 tEMP Cur t boAr LEdS Hi tE boAr LEdS rSEt boAr LEdS VErS IC1 IC2 PErS dM Pr Mod 1 Mod 2 Mod 3 Mod 4 Mod 5 Mod 6 dISP d On On Off d Int 20 100 turn On Off ...

Page 13: ...Menu Level 5 Menu Level 6 tEM U C F bALA On Off C bAL rEd 0 200 255 GrEn 0 255 bLuE 0 237 255 Stor LOAd FuLL EcO In Po rEd1 0 255 F dim 0 255 Stor dFSE MAn M PrE C rEd1 rE1 1 rE1 3 dimr dim0 dim 7 Man C rEd1 0 255 F dim 0 255 TESt St AL Auto Off tESt PrG 1 PrG 3 PLAY tESt PrG 1 ...

Page 14: ...tion test its various parts and lastly program it if it has to be used in a Stand alone mode The four control buttons on the front have the following functions ESCAPE button leaves menu without saving changes ENTER button enters menu confirms adjusted values and leaves menu UP and DOWN buttons move between menu items on the same level sets values After switching the fixture on the fixture display ...

Page 15: ...ful information about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select the required menu item 4 Press the ENTER button to confirm the choice Po ti Power On Time Use the menu item to read the number of operation hours for each LEDs operating mode totL the function shows the total number of ...

Page 16: ...u below I f this function is set off the CitySkape Xtreme will use maximum values 255 of saturation for red green and blue colour This function has to be set on before adjusting a white balance C bAL White Colour Balance The menu gives access to the setting of the white balance To set the white colour balance 1 Use a DMX controller or the Man C menu to set all LEDs on max saturation 2 Use the UP D...

Page 17: ...nk are not connected to the controller but can execute pre set programs which can be different for every fixture Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master MASt and the rest as the slaves SLA Up to 32 fixtu...

Page 18: ...5 module 1 2 bLu1 bLu2 a blue LEDs saturation 0 255 module 1 2 Whi1 Whi2 a white LEDs saturation 0 255 module 1 2 MACr colour macros 0 255 both modules Stro a strobe shutter 0 255 both modules dimr a dimmer 0 255 both modules F tim a fade time 0 25 5 seconds S tim step time value 0 25 5 seconds COPY this item duplicates the current prog step to the next prog step The item P End is increased automa...

Page 19: ...o it 3 Unpack the program from the archive II Fixture software updating 1 Determine which of your port is available on your PC and connect it with the DMX input of the fixture if you using the flash cable RS232 DMX with the DMX input of the Robe Universal Interface if you using the USB cable Disconnect the fixture from the other fixtures in a DMX chain Turn both the computer and the fixture on Mak...

Page 20: ... and the display is dark Restart the Software Uploader program and repeat software update from your PC 7 RDM This fixture is ready for RDM operation RDM Remote Device Management is a bi directional communications protocol for use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protocol allows data packets to be inserted into a DMX...

Page 21: ...e only linked with the transmitter by running the link procedure at DMX transmitter After linking the level of DMX signal 0 100 is displayed in the menu item r InF SPEC rAdI r InF To unlink the fixture from DMX transmitter The fixture can be unlinked from receiver via the menu item r UnL SPEC rAdI r UnL 10 Technical specifications Power supply Electronic auto ranging Input voltage 100 250V AC 50 6...

Page 22: ...odes 6 2 3 4 8 12 control channels Manual control of all effects via control panel Wireless DMX RDM module only for Wireless DMX version Compliance with USITT DMX 512 1986 1990 and 512 A Full DMX fidelity and frame integrity Auto sensing of DMX frame rate and frame size 5ms DMX latency Operational frequency range of 2402 2480 MHz Producer LumenRadio Strobe Strobe effect with variable speed max 20 ...

Page 23: ... 2 x omega holder No 99010420 2 x Frost glass No 14060206 1 x User manual Optional accessories Barn doors No 10980064 Top hat No 10980085 Half top hat No 10980086 Single Top loader case No 10120077 Note By reason of the fast moving development of LED technology newer products may have better light parameters than previous products ...

Page 24: ...washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts If the power supply cable of this device will be damaged cable firmly connected with the device it has to be replaced by authorized distributors only in order to avoid hazards Specifi...

Reviews: