USE 09 MEASURED VALUES AND PARAMETERS
...............................................................................................................................................................................................................
...............................................................................................................................................................................................................
Manual USZ 08 · EN05 · 2015-06
43
I-06
C c-out select
2158
I Current output, selection of the measured value (Modbus reg.)
I-07
C c-out mode
2159
M Current output, operating mode (
OFF
, SET VALUE, 0-20mA, 4-20mA)
I-08
C c-out err mode
2160
M Current output, operating mode if a fault occurs (
OFF
, MIN, MAX)
I-09
C c-out damping
1380
F Current output, damping (0.0=OFF, 1.0=max)
I-10
E c-out gradient
1382
F Current output, gradient
I-11
E c-out offset
1384
F Current output, offset
Serial ports
Value
Unit
Modbus
Description
J-12
N DZU-0 address
2283
I Serial interface -0 DZU slave ID (ASCII: 00-99)
J-13
A serial-0 status
760
T Serial interface -0, status
J-14
N serial-1 mode
2107
M Serial interface -1, mode (OFF,
IGM
, USE09, DZU, DZU-DIAG, DZU
X-FRAME, VO)
J-15
N serial-1 baud rate
baud
2108
M Serial interface -1, baud rate (2400, 4800, 9600, 19200,
38400
, 57600)
J-16
N serial-1 bits
2109
M Serial interface -1, number of bits (7,
8
)
J-17
N serial-1 parity
2110
M Serial interface -1, parity (
NONE
, EVEN, ODD)
J-18
N not available
2286
M Serial interface -1 Modbus operating mode (not yet available)
J-19
N not available
2287
M Serial interface -1 Modbus hardware (not yet available)
J-20
N not available
2288
I Serielle Schnittstelle -1 Modbus address (not yet available)
J-21
N not available
2289
I Serial interface -1 Modbus register offset (not yet available)
J-22
N not available
2290
I Serial interface -1 Modbus turn-off time (not yet available)
J-23
N DZU-1 address
2284
I Serial interface -1 DZU slave ID (ASCII: 00-99)
J-24
A serial-1 status
770
T Serial interface -1, status
J-25
N opt. ser2 mode
2112
M Optional serial interface -2, mode (
OFF
, IGM, USE09, MODBUS,
DZU-SLAVE)
J-26
N opt. ser2 baud rate
baud
2113
M Optional serial interface -2, baud rate (2400, 4800, 9600, 19200,
38400
, 57600)
J-27
N opt. ser2 bits
2114
M Optional serial interface -2, number of bits (7,
8
)
J-28
N opt. ser2 parity
2115
M Optional serial interface -2, parity (
NONE
, EVEN, ODD)
J-29
N Modbus-2 protocol
2178
M Optional serial interface -2, Modbus operating mode (OFF,
RTU
, ASCII)
J-30
N Modbus-2 hw-mode
2179
M Optional serial interface -2, Modbus hardware (RS232,
RS485
)
J-31
N Modbus-2 address
2180
I Optional serial interface -2, Modbus address (ID)
J-32
N Modbus-2 reg.offset
2181
I Optional serial interface -2, Modbus register offset
J-33
N Modbus-2 gap time
2182
I Optional serial interface -2, Modbus gap time
J-34
N long byte order
2251
M Ser-2 Modbus byte order with long: (1,0)(3,2) or (3,2)(1,0) (
Normal
,
SWAPPED)
J-35
N float byte order
2252
M Ser-2 Modbus byte order with float: (1,0)(3,2) or (3,2)(1,0) (
Normal
,
SWAPPED)
J-36
N double byte order
2253
M Ser-2 Modbus byte order with double: (1,0)(3,2)(5,4)(7,6) or
(7,6)(5,4)(3,2)(1,0) (
Normal
, SWAPPED)
J-37
N DZU-2 address
2285
I Serial interface -2 DZU slave ID (ASCII: 00-99)
J-38
A serial-2 status
780
T Optional serial interface -2, status
J-39
E DZU interval
tics
2111
I Serial interface -1, DZU interval
J-40
N DZU checksum preset
2255
M Serial interface -1, initial DZU checksum value (
0x00
, 0x7F)