USE 09 MEASURED VALUES AND PARAMETERS
...............................................................................................................................................................................................................
...............................................................................................................................................................................................................
Manual USZ 08 · EN05 · 2015-06
41
USE09-C flow rate Qm
Value
Unit
Modbus
Description
D-01 A vol. flow rate Qm
&Q
730
T Volumetric flow rate Qm after all corrections (as amount) with
upstream/downstream identification
D-02 A vol. flow rate Qm
&Q
6230
F Volumetric flow rate Qm after all corrections (Qm lower limit will be
observed)
D-03 A Qm damped
&Q
6264
F Volumetric flow rate Qm damped (Qm lower limit will be observed)
D-04 E Qm min.
&Q
1320
F Qm min. limit
D-05 E Qm max.
&Q
1322
F Qm max. limit
D-06 E vw factor d1
[1]
1324
F Constant Kv direction 1
D-07 E vw factor d2
[1]
1436
F Constant Kv direction 2
D-08 E vw lower limit
&v
1326
F vw lower limit (creeping quantity before applying polynomial)
D-09 E Qm lower limit
&Q
1328
F Qm lower limit (creeping quantity)
D-10 E Qm-min time
sek
2120
I Time below Qm min
D-15 C Qm damping
1446
F Damping for Qmc-D (0.0=off, 1.0=max)
D-16 E pipe diameter
mm
1334
F Pipe diameter
D-17 E geometry correcting
2258
M Correction of the effects of pressure and temperature (
OFF
, ON)
D-18 E temp. coefficient
1450
F Temperature coefficient
D-19 E pressure
coeff.
1452
F Pressure
coefficient
D-20 E Qm-max value
&Q
1330
F Qm max. value of direction 1
D-21 E Qm-max time
2580
U Time of Qm max. value
D-22 E Qm-max value
&Q
1332
F Qm max. value of direction 2
D-23 E Qm-max time
2582
U Time of Qm max. value
USE09 parameters
Value
Unit
Modbus
Description
E-01 E USE09 working mode
2090
M USE09 operating mode (
IGM
, USE09C, SIMU)
E-02 E path select
690
T Select activated paths (path 1.1, path 1.2 to path 4.2)
E-03 E max. path RV
2121
I Max. number of replacement values used
E-04 E fault time
s
2122
I Time limit for IGM timeout
E-05 E error per cent
%
2123
I A measurement quality below this level will cause a path error
E-09 E moving average cnt
2125
I Number of measured values for the moving average, V,VOS
E-15 C VOS mode
2240
M VOS mode (
STANDARD
, EXTENDED, CALIBRATION)
E-16 C delta VOS mode
2091
M Delta C monitoring (OFF,
ON
)
E-17 C delta VOS limit
%
1344
F Limit for delta C
E-18 E c-corr factor
[1]
1370
F Factor for C correction
E-19 E v-corr factor
[1]
1372
F Factor for V correction
E-20 C delta AGC limits
dB
1438
F Max. deviation between path-AGC and AGC-mean
E-21 E tw correct
2281
M Correct TWs (
OFF
, SET)
E-22 C tw damping
1518
F Damping for TW adjustment