To activate high impedance on several channels:
1. While the standby screen shows the input level meters, press then hold down the first button. An
instruction is shown on the display and the LEDs next to the TRS input channels change to white (low
impedance) or blue (high impedance).
2. While holding down the button, press the channel buttons next to each TRS input where high
impedance should be activated. A blue LED at the input represents high impedance.
To activate high impedance on a single TRS input channel:
1. Use the button next to the corresponding TRS input to access its settings.
2. Use the
Hi-Z
button to toggle high impedance. The active setting will be highlighted in blue.
High impedance settings are not shown when the channel is switched to XLR input.
9.1.6. Inverting the Phase of an Analog Input Signal
The phase of analog input signals can be inverted at the input.
The setting persists even if the input source is toggled between XLR and TRS.
RME AVB Tool User’s Guide
47
| 9.1. Analog Inputs
Summary of Contents for AVB Tool
Page 2: ...RME AVB Tool User s Guide...