38
IMSRM04-E8
5. COMMUNICATION IDENTIFIERS
5.1 List of Communication Identifiers
( Attributes
RO : Read only R/W : Read and Write WO : Write only)
Name
Iden-
tifier
Digits
Attri-
bute
Data range
Factory
set
value
Refer-
ence
page
Measured value (PV)
input
M1
6
RO
Within input range
−
41
First alarm condition
AA
1
RO
0: OFF 1: ON
−
41
Second alarm condition
AB
1
RO
0: OFF 1: ON
−
Burnout alarm condition
B1
1
RO
0: OFF 1: ON
−
42
Manipulated output
(Heat-side)
O1
6
RO
-5.0 to +105.0 %
−
42
Manipulated output
(Cool-side)
O2
6
RO
-5.0 to +105.0 %
−
Heater break alarm
AC
1
RO
0: OFF 1: ON
−
43
CT input measured
value 1
M3
6
RO
0.0 to 100.0 A or
0.0 to 30.0 A (Measured
value of the TIO module)
−
43
CT input measured
value 2
M4
6
RO
0.0 to 100.0 A or
0.0 to 30.0 A (Measured
value of the CT module)
−
Set value monitor
MS
6
RO
Within input range
−
45
Temperature rise
completion condition
HE
1
RO
0: Rise not complete
1: Rise completed
−
46
Error code
ER
1
RO
0 to 6
−
50
PID/AT transfer
G1
1
R/W
0: PID control operation
1: AT (Autotuning) operation
0
51
Temperature set value
S1
6
R/W
Within input range
(Within setting limiter)
0
53
Heat-side proportional
band
P1
6
R/W
0.1 to 1000.0 % of span
3.0
54
Cool-side proportional
band
P2
6
R/W
0.1 to 1000.0 % of span
3.0
Integral time
I1
6
R/W
1 to 3600 sec.
240
Derivative time
D1
6
R/W
0 to 3600 sec.
60
: Memory area response settings group (See page 62)
Continued on the next page.