3 Unit description
Ritta l crimping machine R8-I
We reserve the right to make technical m odifications
9
EN
Crimping machine R8-I
Air consumption
approx. 0.9 nl / limit stop
Conductor insertion length
35 mm (1.37")
Crimping length
8 mm (0.31")
Wire end ferrules
0.5
–
2.5 mm² (AWG 20 … 14)
Crimping form
Trapezoidal
Cycle time
1.5 s
Ambient temperature
Operation
+5 °C to 40 °C
Storage/transport
-25 °C to +55 °C (short-term +70 °C)
Environmental conditions
Operating environment
Operation in closed and dry spaces / work-
shops
Internal temperature during operation
max. 45 °C
Max. operating altitude
2000 m above mean sea level
Humidity
50% at +40 °C (without condensation), 90%
at +20 °C (without condensation)
Contamination level
2
Continuous sound pressure level
< 70 dB(A)
Dimensions (W x D x H)
390 x 330 x 460 mm (15.35" x 12.99" x
18.11")
Colour
RAL 9003 / RAL 7016
Weight
23 kg (50.71 lbs)
3.2
Rating plate
Symbol
Meaning
Operate automatic machines only in closed and dry
spaces / workshops.
IEC 60417
Reference to the accompanying information or that
attached to the product. Directive 2003/15/EC
European Union
CE labelling
European Eco-
nomic Area
(EEA)
The number of years that the product can be used for
the intended use. SJ/T 11363-2006 (China RoHS)
China