background image

 

 

4.

 

Technical Specifications 

Specification 

Value 

Communication channels band, MHz 

433.075 – 434.775 

No. of communication channels 

Maximum distance for strong signal, 

line-of-sight, m 

up to 800 

Transmitter radiated power, mW 

max 10 

Monitoring period of signaling device 

operation in radio system, min 

Dimensions, mm 

110×90×45 

Weight, g 

160 

Operating temperature range, 

°С

 

40…+55 

Battery, V 

3.6 (AA) lithium battery 

Standalone operation time from one 

battery

1

, yrs 

Up to 3 

Low battery warning 

Yes 

Life cycle, yrs 

min 10 

Enclosure break-in tamper 

Yes 

Visual indicator 

Yes 

 

 

 

                                              

1

 The standalone operation time is directly related to the operating conditions. 

Summary of Contents for RIPR1

Page 1: ...Manual fire radio channel signaling device RIPR1 Data sheet Device identification number Firmware QA specialist Date of check Signature...

Page 2: ...essages low battery signal enclosure break in alarm Receiving these signals by the radio channel receiver RDK1 changes states of receiver outputs for a short time 2 sec Receiving a signal from the sig...

Page 3: ...mW max 10 Monitoring period of signaling device operation in radio system min 4 Dimensions mm 110 90 45 Weight g 160 Operating temperature range 40 55 Battery V 3 6 AA lithium battery Standalone opera...

Page 4: ...ders Respect polarity when installing battery XT1 Connector for alarm additional loop The loop type dry contacts Compatible with normally closed signaling devices without power supply by the loop If t...

Page 5: ...dio system t VD1 green Red Adding is in process The device is switched to the mode for adding to a radio system t The device is successfully added to the system An active device is found It is ready t...

Page 6: ...s up red for 4 seconds and then lights up green for 1 second If the depassivation has not been performed the red indicator lights up red for 2 seconds and then lights up green for 1 second The battery...

Page 7: ...wall surface at a hight of 1 4 1 6 meters from the ground or floor level to the control device and at a distance more than 1 meter from the radio channel receiver Fig 11 1 Fixing holes for signaling d...

Page 8: ...installation and maintenance activities applied to the device should be performed by duly qualified personnel 13 Transportation and Storage The device should be properly packed and transported in roo...