![RITE-HITE Dok-Lok STR-4100 Installation Manual Download Page 15](http://html1.mh-extra.com/html/rite-hite/dok-lok-str-4100/dok-lok-str-4100_installation-manual_1464528015.webp)
Pub. No. 1243 — April 2008
15
RITE-HITE
®
STR-4100 DOK-LOK
®
Installation Manual
INSTALLATION WITH TRENCH DRAIN
1.
If trench drain is below the base plate, embed PVC
pipe in concrete for drainage. Concrete should
extend a minimum of 6 inches to either side of of
mounting plate.
NOTE:
If concrete can not be used, consult factory.
SPECIAL APPLICATION INSTALLATION ITEMS CONT.
FIGURE 17 - TRENCH DRAIN
Embedded PVC Pipe
Overhead View
Side View