NOTE: Panels may come as one or two piece, depending
on the width of the opening.
The fiberglass panels will be shipped without the
nose and bottom seals attached.
Panels are heavy, use caution when moving
and installing.
1.
Apply a generous bead of caulk to the rear edge of the
lead panel.
2.
Lay the two panels together on a flat surface and butt
them up for a tight fit.
3.
Attach the splice bracket between the two panels at the
top.
4.
Fasten bottom seal to the bottom of the panel every 12”
with the Screw, HWH, Dr/Tap, #14 x 1 1/4” provided.
5.
With the cord at the bottom, fasten retention spring
assembly to the outside of the panel by lining up the pre-
drilled holes in the extrusion with the pre-marked holes
on the panel,
Figure 9.
6.
Fasten eyebolt and nut to the panel in the pre-tapped
hole,
Figure 9.
7.
Fasten the blower assembly to the panel using
(1) #14 x 1 1/4" self/tap drill screw provided and plug
cable together,
Figure 9.
8.
Remove the top nut from threaded rods.
9.
Place panel in front of the opening with the threaded rods
at the top,
Figure 8.
10.
Tilt panel such that the threaded rods will slide into the
holes on the trolley, fasten with nuts and washers
removed earlier.
11.
The panel should be adjusted so that the seal is
compressed no more than 1/4” - 3/8” and no light is
showing across the full length of the floor when door is
closed.
VISION FAN OPTION
1.
Mount fan minimum 3” above header and on the center
of the opening. It is recommended to thru-bolt to the wall.
2.
120V, 12 gauge cable with a ground is encouraged for
the power supply (not supplied).
3.
Use the adjustable bracket to aim airflow at the vision,
Figure 10.
BARRIER
®
GLIDER Single Slide Model 7100
PUB. NO. 7100SSG FEBRUARY 2008
9
FIBERGLASS PANEL INSTALLATION
After panel is adjusted, torque nuts as tight as
possible to prevent loosening from vibration and seal
loss.
I M P O R TA N T ! ! !
FIGURE 9
Bottom Seal
Fan Not Present
With Cooler
Door Option
Spring
Assembly
Bottom Seal
Cord/Eyebolt
Insert
Panel Hanger Stud,
Nut and Washer
Lead
Panel
Trail
Panel
Splice Bracket
Caulk Between
Panels
FIGURE 10
Wall
Backer Plate
Blower Mounted 3”
Minimum Above Header