NOTE:

Figure 2 

is for doors that the motor is mounted on 

the jamb side, 

Figure 2A

is for doors that the 

motor is mounted on the storage side.

1.

Place header in front of the opening, by locating the
factory assembled header lifting tubes bolted to the
bottom of the header.

NOTE: If bollard posts are present, and the lifting tubes 

cannot be used, strap around the header tube. The
shorter support post is mounted to the header at 
the side closest to the jamb. Insure that the header
is 7 1/2” above the opening at the end closest to 
the jamb.

2.

Lift the header using the fork lift and bolt the support
posts to the header (posts are free to slide up & down
within the c-channel bracket) and place against the wall,

Figure 2.

3.

Plumb outside of jamb support post 9” past edge of jamb.

4.

Thru-bolt the header to the wall at the (4) top and (2)
bottom mounting angles using the 6” x 6” backer plates,
all thread rods and nuts provided, 

Figure 2 or 2A.

If wall

is not solid, sleeves (not provided) must be used to
prevent wall from crushing and sagging of the header.

5.

Plumb and fasten the support posts to the wall in the 
(4 or 6 based on O.D.H) locations provided with the 6” x 6”
backer plates, all thread rods and nuts provided, 

Figure 2 or 2A.

6.

After header and support posts have been installed,
remove the header lifting tubes and hardware.

BARRIER

®

GLIDER Single Slide Model 7100

4

PUB. NO. 7100SSG  FEBRUARY 2008

HEADER INSTALLATION

FIGURE 2 - JAMB SIDE DRIVE

Panel Trolleys

Panel Stud

Holes

Close Limit Switch

Open Limit Switch

Header

Jamb Side
Shorter
Support Post 

Support Post

Header Mounting

Support Post Wall

Mounting (4-6 Places)

Header Mounting Angle

(6 Places)

CL

Lifting Tubes, Make

Sure to Clamp or Tie to

Fork Lift and Remove

After Complete

9”

It is HIGHLY recommended to thru-bolt the header

with the all threaded rods provided, as this is the

main support for the door.

I M P O R TA N T ! ! !

7 1/2”

Summary of Contents for BARRIER GLIDER 7100

Page 1: ...LIDER SINGLE SLIDE COLD STORAGE DOOR MODEL 7100 PRINTED IN U S A PUBLICATION NO 7100SSG EMAIL PRINTSHOP RITEHITE COM FEBRUARY 2008 This Manual Covers Doors Shipped After 12 17 07 Refer to 7100SSF For Doors Prior ...

Page 2: ...urity Fiberglass Panels Unique Thermal Air Sealing System Impactable Panel Retention System Universal Drive Side RECOMMENDED SERVICE PARTS Bottom Seal Panel Blower Heater Retention Cord Limit Switch Fuses INSTALLATION TOOLS REQUIRED Fork and Scissors Lift 12 Step Ladder 25 Tape Measure 6 Carpenters Level Hydro Level Cordless Drill Wire Strippers Utility Knife Hammer 1 2 Masonry and or Drill Bit fo...

Page 3: ...2 When removing the panels from the crates Be sure not to lean panels such that they crease 13 Remove header from the crate by removing the front and motor side of the crate Slide the motor off the edge of the crate and stand up There will be a block under the C Channel to keep the motor off the floor this will allow a fork lift to pick up the header using the header lifting tubes 14 Remove plasti...

Page 4: ... mounting angles using the 6 x 6 backer plates all thread rods and nuts provided Figure 2 or 2A If wall is not solid sleeves not provided must be used to prevent wall from crushing and sagging of the header 5 Plumb and fasten the support posts to the wall in the 4 or 6 based on O D H locations provided with the 6 x 6 backer plates all thread rods and nuts provided Figure 2 or 2A 6 After header and...

Page 5: ...l Trolleys Panel Stud Holes Close Limit Switch Open Limit Switch Header Support Post Header Mounting Support Post Wall Mounting 4 6 Places Header Mounting Angle 6 Places C L Lifting Tubes Make Sure to Clamp or Tie to Fork Lift and Remove After Complete 9 7 1 2 Jamb Side Support Post Cable Not Present With Cooler Door Option ...

Page 6: ...g of the bag Figure 4 9 After seal installation caulk the entire inside perimeter of the aluminum retainer Failure to do this may result in frost or ice buildup PERIMETER SEAL INSTALLATION FIGURE 3 JAMB SIDE DRIVE Vertical Extension Fastened to Blower BOTH SIDES Air Outlet Hole MUSTNot Be Obstructed Pull SealTaught andTight to the Floor and Screw Retainer to Hold in Place D O W 1 2 D O W O D H 5 3...

Page 7: ...hould be approximately 3 1 2 above the center of the slide rod 4 Slide eyebolt insert onto cord with insert facing up 5 To pre tension the spring pull 6 of cord out tie a knot below the eyebolt insert and then wrap around the slide collar and fasten with cable clamp cut excess cord Figure 6 6 Cord should be tensioned to maintain a 3 1 2 gap from the panel to the wall FIGURE 6 Cord Eyebolt Eyebolt ...

Page 8: ...el on top of lead panel lower bracket slide trail panel into H bracket until the 1 5 8 marks disappear NOTE The top of the panels can be pulled together with the trolley to trolley attachment bolt at the top that was removed earlier If panels are not tight together remove spacer nut Figure 8 12 Attach the trail panel by drilling 17 64 holes in the pre drilled holes on the H bracket and inserting t...

Page 9: ...aded rods 9 Place panel in front of the opening with the threaded rods at the top Figure 8 10 Tilt panel such that the threaded rods will slide into the holes on the trolley fasten with nuts and washers removed earlier 11 The panel should be adjusted so that the seal is compressed no more than 1 4 3 8 and no light is showing across the full length of the floor when door is closed VISION FAN OPTION...

Page 10: ... strain relief Connect cables together 8 This door is powered by 220 575VAC 1Ø or 208 230 460VAC 3Ø ELECTRICAL INSTALLATION In freezer and cooler applications where a conduit passes from a warm to cold temperature zone the conduit must be plugged with epoxy This will help prevent condensation from forming in the conduit For more information see Section 300 7a of the National Electric Code IMPORTAN...

Page 11: ...BARRIER GLIDER Single Slide Model 7100 PUB NO 7100SSG FEBRUARY 2008 11 ELECTRICAL INSTALLATION FIGURE 13 F1 F2 F3 Incoming Power DO NOT Wire Incoming Power Into These Terminals 575V 220V 208 230 460V ...

Page 12: ...reclose or toggle mode 4 For toggle mode the door can be setup such that if a device is used to open the door it or another device needs to be reactivated to close the door DRIVE CHAIN ADJUSTMENT Find the center bracket of the header C Channel Chain should be tensioned so there is 1 between the bottom of the chain and the bottom of C channel LIMIT SWITCH ADJUSTMENT 1 After all parts have been asse...

Page 13: ...OMM controller is a circuit board that controls the actions of the door There is a digital display that shows the cycles status and position of the door at any time during its travel For input and output function signals refer to the chart on this page Settings can be changed for re close or pre announce timers interlocks special activation commands among many others refer to instructional manual ...

Page 14: ...F Hardware Fault The drive has detected a hardware problem verify wiring is correct This cannot be fixed in the field replace the drive HF 05 trip No signal from DSP at start up HF 06 trip Unexpected Interrupt HF 07 trip Watchdog failure HF 08 trip Interrupt crash code overrun HF 11 trip Access to the EEPROM failed HF 20 trip Power stage code error HF 21 trip Power stage unrecognized frame size HF...

Page 15: ...re complete 2 Lift cover and set on stud at the top fasten to the support post Figure 15 Use 14 x 1 hex head self tap drill screw Lock is for Rigid Panel only Install lock per illustration 1 Only attempt to install this lock at the rear edge of a rigid panel 2 Mount the panel lock bracket to the rear of the panel with the U shaped edge overlapping the retainer extrusion The bracket needs to be cen...

Page 16: ...LY REV SHEET UP TO OVER INCH TOLERANCES DO NOT SCALE DRAWING TITLE DATE DATE MM DD YY SIZE SCALE B CHECKED BY APPROVED BY DRAWN BY REF INITIAL ECN DATE ISSUED 0 25 5 1 25 15 80 40 0 125 0 25 1 25 5 15 40 FINISH ANGLES 1 DEG 80 0 040 0 060 0 100 0 125 0 010 0 020 0 030 0 0 125 0 005 DWG NO DATE RITE HITE DOORS INC 8810E035 8810E035 1 1 A A BARRIER GLIDER VFD MANDATORY FIELD WIRING DIAGRAM i COMM LI...

Page 17: ...ER HIGH VOLTAGE 4 2 73100024 TERMINAL END STOP SCREWLESS 2 73100072 TERMINAL PH CAGE 20A 3HOLE 1 73100073 TERMINAL PH CAGE 20A 3HOLE BAR 2 73100076 TERMINAL PH CAGE 20A 3HOLE GND 5 5 51950003 WIRE NUT ORANGE 1 73550017 XFMR 2 0KVA 600 240 120 575V 1 73550024 XFMR 2 0KVA 480 240 240 120 Not 575V PART MODEL NUMBER C APPROVED BY C R REV SHEET DWG NO DESCRIPTION QTY PART NO ITEM PARTS LIST MATERIAL NE...

Page 18: ...BARRIER GLIDER Single Slide Model 7100 18 PUB NO 7100SSG FEBRUARY 2008 WIRING DIAGRAM ...

Page 19: ...LIDE FLEXIBLE PANEL NON STORAGE SIDE MOTOR MOUNT 2 9 2004 4409 4 8 2004 2004 D AC DRIVE 5529 1 15 2008 LIP B ADDED VISION FAN DIMENSIONS 4575 9 13 2004 CDH C UPDATE TITLE BLOCK 4603 11 15 2004 JTD DOOR SYSTEM 8806A003 8806A003 RITE HITE DOORS INC 3 8 1 A A ARCHITECTUAL APPROVAL BARRIER GLIDER SINGLE SLIDE FLEXIBLE PANEL STORAGE SIDE MOTOR MOUNT 10 1 2004 4603 11 15 2004 2004 A AC DRIVE 5529 1 15 2...

Page 20: ...MOUNT 10 4 2004 4603 11 15 2004 2004 A AC DRIVE 5529 1 15 2008 LIP DOOR SYSTEM DOOR SYSTEM RITE HITE DOORS INC A REMOVE DIMENSION A AND UPDATE 4483 7 1 2004 JTD B UPDATE TITLE BLOCK 4603 11 15 2004 JTD C AC DRIVE 5529 1 15 2008 LIP ARCHITECTURAL DRAWINGS RIGID PANEL 20 PUB NO 7100SSG FEBRUARY 2008 BARRIER GLIDER Single Slide Model 7100 ...

Reviews: