PRODUCT INTRODUCTION

TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS   . . . . . . . . . . . . . . . . . . . . . .3

HEADER INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

PERIMETER SEAL INSTALLATION  . . . . . . . . . . . . . . . . . . . .6

RETENTION SYSTEM INSTALLATION   . . . . . . . . . . . . . . . . .7

PANEL INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

ELECTRICAL INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . .10

INPUT / OUTPUT CHART  . . . . . . . . . . . . . . . . . . . . . . . . . . .12

TROUBLESHOOTING / MAINTENANCE  . . . . . . . . . . . . . . .13

FINAL CHECKLIST  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

WIRING DIAGRAMS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

ARCHITECTURAL DRAWING  . . . . . . . . . . . . . . . . . . . . . . . .19

NOTICE TO USER

Our mission is to “Improve Industrial Safety, Security and
Productivity Worldwide Through Quality and Innovation.”

Thank you for purchasing the BARRIER

®

GLIDER from 

RITE-

HITE

DOORS, INC. The BARRIER GLIDER is designed to be a

fast, smooth opening, low maintenance door that provides
superior environmental separation while reducing passage time
and temperature loss.

This manual should be thoroughly read and understood before
beginning the installation, operation or servicing of this door.
Complete Final Checklist prior to leaving site.
Refer to partslist manual for exploded views and part numbers.

This owners manual MUST be stored near the door.

RITE-HITE

DOORS, INC. reserves the right to modify the

electrical and architectural drawings in this manual as well as
the actual parts used on this product are subject to
manufacturing changes and may be different than shown in this
manual. Due to unique circumstances with varying
requirements, separate prints may be included with the unit.

The information contained in this manual will allow you to
operate and maintain the door in a manner which will insure
maximum life and trouble free operation. The serial # for your
door is on a label located on the side of the control box and
support post.

Your local 

RITE-HITE

DOORS, INC. Representative provides

the Planned Maintenance Program (P.M.P.) which can be fitted
to your specific operation. If any procedures for the installation,
operation or maintenance of the BARRIER GLIDER have been
left out of this manual or are not complete, contact 

RITE-HITE

DOORS, INC. Technical Support at 1-563-589-2722.

RITE-HITE

DOORS, INC. are covered by one or more of the

following U.S. patents, including patents applied for, pending, or
issued: 5,025,846, 5,143,137, 5,203,175, 5,329,781, 5,353,859,
5,392,836, 5,450,890, 5,542,463, 5,579,820, 5,601,134,
5,638,883, 5,655,591, 5,730,197, 5,743,317, 5,794,678,
5,887,385, 5,915,448, 5,944,086, 5,957,187, 6,042,158,
6,089,305, 6,098,695, 6,145,571, 6,148,897, 6,192,960,
6,321,822, 6,325,195, 6,330,763, 6,352,097, 6,360,487,
6,574,832, 6,598,648, 6,612,357, 6,615,898, 6,659,158 

SPECIAL FEATURES

• i-COMM™ Universal Controller

• Energy Efficient Design Featuring High R-Value Panels

• Flexible or High Security Fiberglass Panels

• Unique Thermal Air Sealing System

• Impactable Panel Retention System

• Universal Drive Side

RECOMMENDED SERVICE PARTS

Bottom Seal

Panel Blower/Heater

Retention Cord

Limit Switch

Fuses

INSTALLATION TOOLS REQUIRED

Fork and Scissors Lift
12’ Step Ladder
25’ Tape Measure
6’ Carpenters Level
Hydro Level
Cordless Drill
Wire Strippers
Utility Knife
Hammer
1/2” Masonry and/or Drill Bit for thru bolting
7/16”, 1/2”, 9/16” Open End and/or Socket Wrench
(2) 15/16” Open End Wrenches
11/16” x 12” Drill Bit for thru bolting
Straight Screwdriver (small 1/8” spade)

Hardware for mounting the header, support posts, retention rod,
blower and perimeter seals to wall are provided. Caulk for
perimeter seals is not provided.

WARRANTY

RITE-HITE

DOORS, INC. warrants that it’s BARRIER

®

GLIDER

door will be free from defects in design, materials, and
workmanship for 150,000 cycles or for a period of one (1) year
from the date of shipment. The panel fabric warranty covers
material failure under normal wear conditions; it does not cover
labor or damage incurred from abuse, misuse or impact.
Warranty does not cover wear items such as seals, belts, fuses,
and bulbs. All claims for breach of this warranty must be made
within thirty (30) days after the defect is or can, with reasonable
care, be discovered. To be entitled to the benefits of this
warranty, the products must have been properly installed,
maintained, operated within their rated capacities, and not
otherwise abused. Periodic lubrication and adjustment are the
sole responsibility of the owner. This is 

RITE-HITE

DOORS,

INC. exclusive warranty. 

RITE-HITE

DOORS, INC. expressly

disclaims all implied warranties of merchantability and fitness.
Non-standard 

RITE-HITE

DOORS, INC. warranties, if any, must

be specified by 

RITE-HITE

DOORS, INC. in writing.

In the event of any defects covered by this warranty, 

RITE-HITE

DOORS, INC. will remedy such defects by repairing or
replacing any defective equipment or parts, bearing all of the
costs for parts, labor, and transportation. This shall be the
exclusive remedy for all claims whether based on contract
negligence or strict liability. Neither 

RITE-HITE

DOORS, INC.,

RITE-HITE

DOORS, INC. representatives or any other

manufacturer whose products are the subject of this
transaction, shall in any event be liable for any loss or use of
any equipment or incidental or consequential damages of any
kind whether for breach of warranty, negligence, or strict liability.
The application of a manufacturer's specifications to a particular
job is the responsibility of the purchaser.

RITE-HITE

DOORS, INC.

8900 N. Arbon Drive

P.O. Box 245020

Milwaukee, Wisconsin 53224-9520

Sales: 414-355-2600

Toll Free: 800-456-0600

Aftermarket: 563-589-2781

Service:  563-589-2722

Service Fax:  563-589-2737

Representatives in All Major Cities

www.ritehite.com

Summary of Contents for BARRIER GLIDER 7100

Page 1: ...LIDER SINGLE SLIDE COLD STORAGE DOOR MODEL 7100 PRINTED IN U S A PUBLICATION NO 7100SSG EMAIL PRINTSHOP RITEHITE COM FEBRUARY 2008 This Manual Covers Doors Shipped After 12 17 07 Refer to 7100SSF For Doors Prior ...

Page 2: ...urity Fiberglass Panels Unique Thermal Air Sealing System Impactable Panel Retention System Universal Drive Side RECOMMENDED SERVICE PARTS Bottom Seal Panel Blower Heater Retention Cord Limit Switch Fuses INSTALLATION TOOLS REQUIRED Fork and Scissors Lift 12 Step Ladder 25 Tape Measure 6 Carpenters Level Hydro Level Cordless Drill Wire Strippers Utility Knife Hammer 1 2 Masonry and or Drill Bit fo...

Page 3: ...2 When removing the panels from the crates Be sure not to lean panels such that they crease 13 Remove header from the crate by removing the front and motor side of the crate Slide the motor off the edge of the crate and stand up There will be a block under the C Channel to keep the motor off the floor this will allow a fork lift to pick up the header using the header lifting tubes 14 Remove plasti...

Page 4: ... mounting angles using the 6 x 6 backer plates all thread rods and nuts provided Figure 2 or 2A If wall is not solid sleeves not provided must be used to prevent wall from crushing and sagging of the header 5 Plumb and fasten the support posts to the wall in the 4 or 6 based on O D H locations provided with the 6 x 6 backer plates all thread rods and nuts provided Figure 2 or 2A 6 After header and...

Page 5: ...l Trolleys Panel Stud Holes Close Limit Switch Open Limit Switch Header Support Post Header Mounting Support Post Wall Mounting 4 6 Places Header Mounting Angle 6 Places C L Lifting Tubes Make Sure to Clamp or Tie to Fork Lift and Remove After Complete 9 7 1 2 Jamb Side Support Post Cable Not Present With Cooler Door Option ...

Page 6: ...g of the bag Figure 4 9 After seal installation caulk the entire inside perimeter of the aluminum retainer Failure to do this may result in frost or ice buildup PERIMETER SEAL INSTALLATION FIGURE 3 JAMB SIDE DRIVE Vertical Extension Fastened to Blower BOTH SIDES Air Outlet Hole MUSTNot Be Obstructed Pull SealTaught andTight to the Floor and Screw Retainer to Hold in Place D O W 1 2 D O W O D H 5 3...

Page 7: ...hould be approximately 3 1 2 above the center of the slide rod 4 Slide eyebolt insert onto cord with insert facing up 5 To pre tension the spring pull 6 of cord out tie a knot below the eyebolt insert and then wrap around the slide collar and fasten with cable clamp cut excess cord Figure 6 6 Cord should be tensioned to maintain a 3 1 2 gap from the panel to the wall FIGURE 6 Cord Eyebolt Eyebolt ...

Page 8: ...el on top of lead panel lower bracket slide trail panel into H bracket until the 1 5 8 marks disappear NOTE The top of the panels can be pulled together with the trolley to trolley attachment bolt at the top that was removed earlier If panels are not tight together remove spacer nut Figure 8 12 Attach the trail panel by drilling 17 64 holes in the pre drilled holes on the H bracket and inserting t...

Page 9: ...aded rods 9 Place panel in front of the opening with the threaded rods at the top Figure 8 10 Tilt panel such that the threaded rods will slide into the holes on the trolley fasten with nuts and washers removed earlier 11 The panel should be adjusted so that the seal is compressed no more than 1 4 3 8 and no light is showing across the full length of the floor when door is closed VISION FAN OPTION...

Page 10: ... strain relief Connect cables together 8 This door is powered by 220 575VAC 1Ø or 208 230 460VAC 3Ø ELECTRICAL INSTALLATION In freezer and cooler applications where a conduit passes from a warm to cold temperature zone the conduit must be plugged with epoxy This will help prevent condensation from forming in the conduit For more information see Section 300 7a of the National Electric Code IMPORTAN...

Page 11: ...BARRIER GLIDER Single Slide Model 7100 PUB NO 7100SSG FEBRUARY 2008 11 ELECTRICAL INSTALLATION FIGURE 13 F1 F2 F3 Incoming Power DO NOT Wire Incoming Power Into These Terminals 575V 220V 208 230 460V ...

Page 12: ...reclose or toggle mode 4 For toggle mode the door can be setup such that if a device is used to open the door it or another device needs to be reactivated to close the door DRIVE CHAIN ADJUSTMENT Find the center bracket of the header C Channel Chain should be tensioned so there is 1 between the bottom of the chain and the bottom of C channel LIMIT SWITCH ADJUSTMENT 1 After all parts have been asse...

Page 13: ...OMM controller is a circuit board that controls the actions of the door There is a digital display that shows the cycles status and position of the door at any time during its travel For input and output function signals refer to the chart on this page Settings can be changed for re close or pre announce timers interlocks special activation commands among many others refer to instructional manual ...

Page 14: ...F Hardware Fault The drive has detected a hardware problem verify wiring is correct This cannot be fixed in the field replace the drive HF 05 trip No signal from DSP at start up HF 06 trip Unexpected Interrupt HF 07 trip Watchdog failure HF 08 trip Interrupt crash code overrun HF 11 trip Access to the EEPROM failed HF 20 trip Power stage code error HF 21 trip Power stage unrecognized frame size HF...

Page 15: ...re complete 2 Lift cover and set on stud at the top fasten to the support post Figure 15 Use 14 x 1 hex head self tap drill screw Lock is for Rigid Panel only Install lock per illustration 1 Only attempt to install this lock at the rear edge of a rigid panel 2 Mount the panel lock bracket to the rear of the panel with the U shaped edge overlapping the retainer extrusion The bracket needs to be cen...

Page 16: ...LY REV SHEET UP TO OVER INCH TOLERANCES DO NOT SCALE DRAWING TITLE DATE DATE MM DD YY SIZE SCALE B CHECKED BY APPROVED BY DRAWN BY REF INITIAL ECN DATE ISSUED 0 25 5 1 25 15 80 40 0 125 0 25 1 25 5 15 40 FINISH ANGLES 1 DEG 80 0 040 0 060 0 100 0 125 0 010 0 020 0 030 0 0 125 0 005 DWG NO DATE RITE HITE DOORS INC 8810E035 8810E035 1 1 A A BARRIER GLIDER VFD MANDATORY FIELD WIRING DIAGRAM i COMM LI...

Page 17: ...ER HIGH VOLTAGE 4 2 73100024 TERMINAL END STOP SCREWLESS 2 73100072 TERMINAL PH CAGE 20A 3HOLE 1 73100073 TERMINAL PH CAGE 20A 3HOLE BAR 2 73100076 TERMINAL PH CAGE 20A 3HOLE GND 5 5 51950003 WIRE NUT ORANGE 1 73550017 XFMR 2 0KVA 600 240 120 575V 1 73550024 XFMR 2 0KVA 480 240 240 120 Not 575V PART MODEL NUMBER C APPROVED BY C R REV SHEET DWG NO DESCRIPTION QTY PART NO ITEM PARTS LIST MATERIAL NE...

Page 18: ...BARRIER GLIDER Single Slide Model 7100 18 PUB NO 7100SSG FEBRUARY 2008 WIRING DIAGRAM ...

Page 19: ...LIDE FLEXIBLE PANEL NON STORAGE SIDE MOTOR MOUNT 2 9 2004 4409 4 8 2004 2004 D AC DRIVE 5529 1 15 2008 LIP B ADDED VISION FAN DIMENSIONS 4575 9 13 2004 CDH C UPDATE TITLE BLOCK 4603 11 15 2004 JTD DOOR SYSTEM 8806A003 8806A003 RITE HITE DOORS INC 3 8 1 A A ARCHITECTUAL APPROVAL BARRIER GLIDER SINGLE SLIDE FLEXIBLE PANEL STORAGE SIDE MOTOR MOUNT 10 1 2004 4603 11 15 2004 2004 A AC DRIVE 5529 1 15 2...

Page 20: ...MOUNT 10 4 2004 4603 11 15 2004 2004 A AC DRIVE 5529 1 15 2008 LIP DOOR SYSTEM DOOR SYSTEM RITE HITE DOORS INC A REMOVE DIMENSION A AND UPDATE 4483 7 1 2004 JTD B UPDATE TITLE BLOCK 4603 11 15 2004 JTD C AC DRIVE 5529 1 15 2008 LIP ARCHITECTURAL DRAWINGS RIGID PANEL 20 PUB NO 7100SSG FEBRUARY 2008 BARRIER GLIDER Single Slide Model 7100 ...

Reviews: