BARRIER
®
GLIDER Single Slide Model 7100
12
PUB. NO. 7100SSG FEBRUARY 2008
OPERATING PROCEDURE
1.
To operate the door, simply press the green open button
on the front of the control box, the door should go to the
full open position.
2.
Normal settings are set to auto-reclose, and once the
open button is pressed the door will open, time out per the
setting of the re-close timer on the i-COMM and close.
3.
The door can be equipped with several types of
activation devices that can open or close the door and
can be setup to either auto-reclose or toggle mode.
4.
For toggle mode, the door can be setup such that if a
device is used to open the door, it or another device
needs to be reactivated to close the door.
DRIVE CHAIN ADJUSTMENT
Find the center bracket of the header C-Channel. Chain
should be tensioned so there is 1” between the bottom of
the chain and the bottom of C-channel.
LIMIT SWITCH ADJUSTMENT
1.
After all parts have been assembled to the door, place
the door in the closed position with the closed limit switch
tripped.
2.
Open the door and set the open limit so the panels are
clear of the opening,
Figure 14.
3.
Limit switches are preset at a 10° angle toward each other.
INPUT / OUTPUT CHART / OPERATING PROCEDURE
FIGURE 14
Panel
Header
Limit Switch
Connection