P.
Float Adjustment
– Open water-supply shut-off valve, check for and fix any leaks. Adjust float for a
water depth of 2 inches below top of trough by adjusting the thumbscrew.
Q.
Install Side Access Panel
and Close Lid
– Once all water line connections have been checked for
leaks and electrical hook-up is complete, the side access door may be installed. After valve is checked to
make sure it is functioning properly and the water level is set to the proper height, you may close and lock
down the lid.
R.
Children should be supervised to ensure that they do not play with the appliance –
This
appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions
concerning use of the appliance by a person responsible for their safety.
S.
Cleaning Your Fountain
– To clean your watering fountain you will need a good stiff bristled brush.
Open the hinged cover and brush the inside of the valve chamber to remove any build-up then brush the
rest of fountain. Remove drain plugs to drain out the water and debris. You can shut off the water with the
shut-off valve located under the unit or by holding the float in the up position. After the water and debris
has drained reinstall the plugs and let the tank refill. Now is a good time to readjust the float if needed.
Reinstall cover and you are done.
Ritchie Valves
Ritchie valves come in various sizes and pressure ratings as shown below - green for high supply line
pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the
size of trough also impacts valve choice. Although different pressure rated valves may be used in a
fountain, each fountain will only accommodate one size and configuration of valve. Your individual
situations may require a change from the standard valve supplied with your fountain, see your Ritchie
Dealer if this is needed.
NOTE
:
The green ¾” valve is standard on the OmniMaster 8
.
NOTE: Maximum inlet water pressure for each valve is shown above. If water pressure is
extremely high, and if the valve does not shut off, a pressure-reducing valve may be needed.
3/4”
Part #
GPM
Pressure Range
White
16697
33
Low, 5-40 psi (34-275 kPa)
Red
11101
20
Moderate, 40-60 psi (275-414 kPa)
Green
15377
16.5
High, 60-80 psi (414-552 kPa)
OmniMaster Series Instruction Manual
6
11 October, 2017