D.
Riser Tube
- Install a riser tube and extend it at least one foot below frost line or down to horizontal
underground water line. For optimum water line protection, use the 12” diameter insulated
Ritchie
Thermal Tube
, part numbers and sizes are shown to the right. Tube opening
must be kept clear.
NOTE: The supply line touching the riser tube is the most common
cause of the supply line freezing. Do not surround the supply line with
insulation, wood, or other foreign material. Any foreign material in the
tube may cause frost to migrate to the supply line causing it to freeze.
E.
Mounting Platform
- A concrete platform must be provided for all fountains. Use a minimum of 4”
thick, (6” recommended thickness), large enough to accommodate fountain, and additional 4” step (on top
of the platform) extending 18” out from each side of the unit. This will protect the unit from manure
handling equipment, as well as discouraging animals from defecating in the fountain. Extending the
platform provides animals a place to stand while drinking, consider the size of your animals when
determining the dimensions of your platform. The concrete step and platform should slope away from the
fountain for drainage. A rough broom finish to concrete surface provides better footing for livestock.
F.
Anchoring Fountain
– OmniMaster 8 fountains have mounting pockets molded into the base: Use
the pockets at each end when installing the unit flush against a wall. Use of Ritchie part #16555, stainless
steel anchor bolts (not included), is recommended. Once you have verified the positioning of the fountain,
drill, install, and tighten down anchor bolts. Use the large washers provided to hold unit down. Tighten
hold down anchors tight, but do not over tighten as this could damage the plastic feet. Use an all-weather
sealant under the outside edge when anchoring to concrete to keep air from leaking under fountain.
G.
Preparing the bottom -
Apply the provided foam weather stripping to the bottom of the unit, along
the outside edge of the fountain.
H.
Hose Connection
- Connect hose fitting to shut-off valve at top of concrete. Slip on barb fitting with
furnished clamps. Hose should not touch insulation or outside surface of fountain. Place the hose under
the fountain as you move the unit in place over the riser tube.
Ritchie Thermal Tube
Part #
Description
18158
1’ Top Section
16417
2’ Top Section
16612
4’ Top Section
16416
2’ Extension
OmniMaster Series Instruction Manual
2
11 October, 2017