background image

This appliance shall be installed in accordance with:

•  Manufacturer’s Installation Instructions

•  Current AS/NZS 3000, AS/NZS 3500 & AS 5601 

•  Local Regulations and Municipal Building Codes  

This appliance must be installed, serviced and removed by an Authorised Person.

All Rinnai gas products

are A.G.A. certified.

Distributed and serviced in Australia under a Quality 
System certified as complying with ISO 9001 by SAI 
Global

Luminaire® Outdoor Gas Fire

Operation / Installation Manual

Models:

 

ROF4500, 4501, 

4502, 4100, 4101, 4102

A luminous effect appliance. Not certified as a space heater.

FOR OUTDOOR USE ONLY - this appliance shall not be installed or used indoors 

Summary of Contents for ROF4100

Page 1: ...ed and removed by an Authorised Person AllRinnaigasproducts areA G A certified Distributed and serviced in Australia under a Quality System certified as complying with ISO 9001 by SAI Global Luminaire Outdoor Gas Fire Operation Installation Manual Models ROF4500 4501 4502 4100 4101 4102 A luminous effect appliance Not certified as a space heater FOR OUTDOOR USE ONLY this appliance shall not be ins...

Page 2: ...Luminaire Outdoor Gas Fire DO NOT operate in an unventilated area Refer to page 7 for details DO NOT obstruct the flow of air around this appliance whilst in use Refer to Clearances and Location section page 7 Certain materials or items when placed near the Rinnai Luminaire Outdoor Gas Fire may be affected by the radiant heat and could be damaged Keep all items away from your Rinnai Luminaire Outd...

Page 3: ...ION OPERATION 8 ABNORMAL FLAME PATTERN 9 INSTALLERS INFORMATION TROUBLESHOOTING 9 SERVICING 9 SPECIFICATIONS 10 INSTALLATION APPLICATIONS 12 GAS CONNECTION 13 APPLIANCE LOCATION 14 KITSET INSTALLATION NON COMBUSTIBLE FRAME 15 KITSET INSTALLATION COMBUSTIBLE FRAME 16 DOOR ASSEMBLY 17 FASCIA INSTALLATION 19 MASONRY INSTALLATION 21 FREESTANDING UNIT 22 BURNER MATERIAL 22 CHECKLIST 23 INSTALLERS GAS F...

Page 4: ...ntel x 1 Stainless Steel Weather Coverx1 Two Sided See Through Unit Burner and Box Assembly x 1 Granite Cover x 2 Granite Trim x 6 Pumice Stones Pebbles x 1 each Fascia Trim Kit Components x2 Instruction Manual Warranty Sheet LP Hose Regulator Assy x 1 Angle Brackets x 4 Lintel x 2 Stainless Steel Weather Coverx1 Granite Trim x 6 Granite Cover x 2 Granite Trim x 6 Granite Cover x 2 M4 x 8 Pan head...

Page 5: ...ual Accessories Glass Door Kit M4 x 8 4 pieces M5 x 10 2 pieces Fascia Trim Kit Components x 1 Universal LPG NG Gas Conversion Kit M4 x 8 Pan head 10pcs M5 x 10 Pan head 8pcs Trim Bracket 4pcs Left side Trim 1pce Bottom Trim 1pce Top Trim 1pce Right side Trim 1pce ACCESSORIES CONTENTS ...

Page 6: ...able contents or an inflammable propellant which may ignite creating a dangerous situation Do not use or store flammable materials near this appliance Keep unit away from combustible materials Combustible materials must not be placed where the unit could ignite them Appliance must be secured into a permanent fixture Solid fuels shall not be burned in this Rinnai Luminaire Outdoor Gas Fire Ensure n...

Page 7: ...e 4 The isolation valve must be closed when the Rinnai Luminaire Outdoor Gas Fire is not in use Failure to comply with these Instructions could result in a fire or explosion which could cause serious injury death or property damage This appliance must be installed and commissioned by an authorised person only This is a permanently fixed luminous effect appliance for outdoor areas only Not to be us...

Page 8: ...he hose must be replaced if damaged or when local regulations require this Contact your supplier or local regulating authority if uncertain Such replacement must only be carried out by an authorised person Gas Cylinder 1 This Rinnai Luminaire Outdoor Gas Fire is designed for use with a 9 kg LP Gas cylinder This cylinder should conform to AS 2030 1 1999 2 The Rinnai Luminaire Outdoor Gas Fire is de...

Page 9: ...apy solution to all visible gas connections in the vicinity of the cylinder and regulator Gas leaks will show as small bubbles gradually increasing in size in the soapy solution Step 7 If there is a gas leak from the connection between the regulator and gas cylinder close the gas valve on the cylinder by turning it clockwise Disconnect the regulator and hose assembly from the cylinder by turning t...

Page 10: ... stagnant areas and where gas leakage and products of combustion are rapidly dispersed by wind and natural convection The following figures are diagrammatic representations of Outdoor Use as defined An enclosure with walls on all sides but with at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no more than 2 walls Wi...

Page 11: ... further 5 seconds to active the flame and then release Steps 1 2 may need repeated several times to ignition the Fire If main burner has not ignited within 5 attempts see troubleshooting section refer to page 9 Step 3 Once the appliance is on it is best to run on a high setting for a period of time in order to establish a flame pattern and allow the unit to heat up approximately 30 minutes You ca...

Page 12: ... is correct for appliance Faulty control valve Contact Rinnai see details page 23 No Spark Minor popping sound during ignition Unburnt gas coming through pumice stones igniting No action normal operation Major popping sound during ignition or during operation Incorrect gas type Check gas type is correct for appliance Damaged burner Contact Rinnai see details page 23 Blocked burner Inspect and clea...

Page 13: ...ylinder Quick Disconnect QDC Rectus Type 21 NG 5 8 UNF flared connection to NG Regulator Ignition System Intermittent pilot Input ULPG 45 25 MJ h High to Low NG 41 22 MJ h High to Low Pilot SIT single injector pilot assembly with fixed aeration and replaceable fixed pilot injector for NG and ULPG Pilot assembly also contains a pilot ignition electrode and thermocouple for flame failure Internal Pi...

Page 14: ... on the appliance when the flame is on Body Assembly Open One Sided Cabinet The outer body assembly is optional and must be used if installing into a non combustible enclosure It consists of a 5 sided construction with an open front pictured or open front and back If a body assembly is ordered this comes assembled complete with burner assembly inside Enclosure must be constructed of masonry or non...

Page 15: ...onal accessories Installation Components Needed Optional Accessories Freestanding Unit Burner Assembly Universal LPG NG Conversion Kit Open One Sided Unit One Sided Assembly Glass Bi Fold Doors NG Conversion Kit Open Two Sided See Through Unit Burner Assembly Universal LPG Glass Bi fold Doors NG Conversion Kit Non combustible enclosed masonry open one or two sides Burner Assembly Universal LPG NG ...

Page 16: ...iance Bubbles will appear if connections are not properly sealed Tighten or rectify as necessary and retest Step 5 Refer to page 6 for full instructions Fixed Universal LPG and NG Connections Fixed Universal LPG connection A 3 8 BSP fixed connection is also supplied with this unit This connection is for installations connected to a permanent fixed Universal LPG connection that supplies gas to othe...

Page 17: ...nbuilt 100 mm minimum Freestanding 900 mm minimum Ground level to bottom of fireplace Walls D 500 mm Side of unit to side wall Gas Meters 1000 mm Drain of Soil Pipe 150 mm Openable Windows and doors 1000 mm From an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation Mechanical Air Inlet 2000 mm For example air conditioni...

Page 18: ...ly into frame When purchasing a cabinet option the body and burner come pre assembled simply unpack fit and secure assembly into the frame using bottom fascia brackets For the see through unit you will need to ensure the control knob is facing the correct way for easy operation Drill hole in bottom bracket and fit screw to secure assembly Above Side Below Behind 500 mm 25 mm 0 mm 30 mm One sided c...

Page 19: ...atures The minimum distance above the unit to a combustible frame is 500 mm To fit Step 1 Take out and undo four fastenening screws at either end Step 2 Flip side sections 180 and loosely refit screws Step 3 Adjust to desired length before tightening Angled clearance brackets Designed to ensure combustible framing is greater than 25 mm from the sides of the unit as shown Top View Open One Sided Ca...

Page 20: ...s where a cabinet also called a body assembly has been installed The unit can operate with the doors open or closed however for best radiant heat the doors should be open during operation Suitable for Non Combustible cladding and frame materials Rinnai accepts no responsibility for deterioration of cladding or finishes Cabinet installation door assembly is suitable Only has a burner assembly insta...

Page 21: ...e burner assembly needs to be fitted back into the cabinet Simply reinstall by reversing steps taken to remove it refer page 19 Component Quantity 1 Left hand glass panel and surround 1 2 Right hand glass panel and surround 1 3 Swing arm kit 1 Screws M4 x 8 for fitting swing arms into cabinet 4 Screws M5 x 10 for fitting swing arms to doors 2 Fit door swing arms Remove left and right swing arms fr...

Page 22: ...oor Gas Fire Removing the frame Step 1 Remove the 2 pcs M4 x 8 underside screws from the bottom of the frame Step 2 Detach frame from the bottom swing out and lift off the top of the upper frame bracket Step 3 Remove the 4 frame brackets Removing the burner assembly The burner assembly weighs approximately 20 kg if required seek additional assistance in lifting You may also want to remove some of ...

Page 23: ...el has two holes for securing see image Step 3 Remove the protective PVC coating from all panels Step 4 On a flat clean surface assemble the top side and bottom fascia panels using the 8 pcs M4 x 8 screws supplied Step 5 Fit the four frame mounting brackets to the cabinet frame using the 8 pcs M5 x 10 screws supplied Step 6 Position the fascia assembly by hooking the top fascia panel over the top ...

Page 24: ...ons provided above Remember to allow for a gas connection opening below the burner as shown below Ensure the opening is large enough for the flexible connection to fit through A suggested hole size is detailed below Gas positioning diagram Install burner assembly Install burner assembly into non combustible surround and fix in place with appropriate fasteners Minimum Dimensions mm A 500 B 1150 C 4...

Page 25: ... level to the bottom of the granite trims Not all the pumice will be needed as more has been supplied than necessary Keep remainder for top up next season Avoid pouring over the burner dust particles can clog the burner ports Ensure burner is not deeply buried by the pumice Layer 2 Quartz Stones Using all the small quartz stones provided place a single layer of small quartz stones evenly covering ...

Page 26: ...oating material is removed before operating the unit If you have answered no to any of the above questions you must not allow the appliance to be operated until the item has been rectified WARNING Company name ____________________________________________________ Installers name ____________________________________________________ Address ____________________________________________________ _______...

Page 27: ...Notes ...

Page 28: ...arts Technical Info Tel 1300 555 545 Fax 1300 300 141 Cost of a local call Higher from mobile or public phones Australia Pty Ltd ABN 74 005 138 769 Internet www rinnai com au E mail enquiry rinnai com au Internet www rinnai co nz E mail sales rinnai co nz Head Office New Zealand 105 Pavilion Drive Airport Oaks Mangere New Zealand Tel 09 625 4285 Fax 09 624 3018 24 Hour Service Tel 0800 746624 0800...

Reviews: