Rinnai Luminaire® Outdoor Gas Fire - Operation and Installation Manual
Clearances
The following minimum clearances from combustible materials must be maintained:
• Top: 1000 mm - measured from top of cover in the closed position.
• Rear: 1000 mm - measured from the rear main panel.
• Sides: 300 mm - measured from the side main panel.
• Openings around the base of the appliance provide air for cooling and combustion and must not be
obstructed.
Location
‘Outdoor Use’ is defined as use in an above ground, open air situation with natural ventilation, without
stagnant areas and where gas leakage and products of combustion are rapidly dispersed by wind and
natural convection.
The following figures are diagrammatic representations of ‘Outdoor Use’ as defined:
An enclosure with walls on all sides, but
with at least one permanent opening at
ground level and no overhead cover.
Within a partial enclosure that includes an
overhead cover and no more than 2 walls.
Within a partial enclosure that includes an
overhead cover and more than 2 walls the
following shall apply:
• At least 25% of the total wall area is
completely open and
• At least 30% of the remaining wall area
is open and unrestricted.
In the case of balconies at least 20% of
the total wall area shall be and remain
open and unrestricted.
CLEARANCES AND LOCATION